Dosimetric comparison between RapidArc and HyperArc in hippocampal-sparing whole-brain radiotherapy with a
Jeongho Kim1, Tae Gyu Kim1, Byungdo Park1
1Departments of Radiation Oncology, Samsung Changwon Hospital, Sungkyunkwan University School of Medicine, Changwon, South Korea.
Abstract:
The HyperArc technique is known for generating high-quality radiosurgical treatment plans for intracranial lesions or hippocampal-sparing whole-brain radiotherapy (WBRT). However, there is no reported feasibility of using the HyperArc technique in hippocampal-sparing WBRT with a simultaneous integrated boost (SIB). This study aimed to compare dosimetric parameters of 2 commercially-available volumetric-modulated arc radiotherapy techniques, HyperArc and RapidArc, when using hippocampal-sparing WBRT with a SIB to treat brain metastases. Treatment plans using HyperArc and RapidArc techniques were generated retrospectively for 19 previously treated patients (1 to 3 brain metastases). The planning target volumes for the whole brain (excluding the hippocampal avoidance region; PTVWB) and metastases (PTVmet) were prescribed 25 and 45 Gy, respectively, in 10 fractions. Each plan included homogeneous and inhomogeneous delivery to the PTVmet. Dosimetric parameters for the target (conformity index [CI], homogeneity index [HI], target coverage [D95%]), and nontarget organs at risk were compared for the HyperArc and RapidArc plans. For homogeneous delivery, dosimetric parameters, including mean CI, HI, and target coverage in PTVWB and PTVmet, were superior for HyperArc than RapidArc plans (all p < 0.01). The PTVWB and PTVmet target coverage for HyperArc plans was significantly greater than for RapidArc plans (96.17% vs 93.38%, p < 0.01; 94.02% vs 92.21%, p < 0.01, respectively). HyperArc plans had significantly lower mean hippocampal Dmax and Dmin values than RapidArc plans (Dmax: 15.53 Gy vs, 16.71 Gy, p < 0.01; Dmin: 8.33 Gy vs 8.93 Gy, p < 0.01, respectively). Similarly, inhomogeneous delivery of hyperArc produced a superior target and lower hippocampal dosimetric parameters than RapidArc, except for the HI of PTVmet (all p < 0.01). HyperArc generated superior conformity and target coverage with lower hippocampal doses than RapidArc. HyperArc could be an attractive technique for hippocampal-sparing WBRT with an SIB.
Related Concept Videos
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...