Related Experiment Video
Updated: Jul 16, 2025

Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
Investigation on the physical dose filtered by linear energy transfer for treatment plan evaluation in carbon ion
Mansure Schafasand1,2, Andreas Franz Resch1, Ankita Nachankar1,3
1MedAustron Ion Therapy Center, Wiener Neustadt, Austria.
Background:
Large tumor size has been reported as a predicting factor for inferior clinical outcome in carbon ion radiotherapy (CIRT). Besides the clinical factors accompanied with such tumors, larger tumors receive typically more low linear energy transfer (LET) contributions than small ones which may be the underlying physical cause. Although dose averaged LET is often used as a single parameter descriptor to quantify the beam quality, there is no evidence that this parameter is the optimal clinical predictor for the complex mixed radiation fields in CIRT.
Purpose:
Purpose of this study was to investigate on a novel dosimetric quantity, namely high-LET-dose ( , the physical dose filtered based on an LET threshold) as a single parameter estimator to differentiate between carbon ion treatment plans (cTP) with a small and large tumor volume.
Methods:
Ten cTPs with a planning target volume, (large) and nine with a (small) were selected for this study. To find a reasonable LET threshold ( ) that results in a significant difference in terms of , the voxel based normalized high-LET-dose ( ) distribution in the clinical target volume (CTV) was studied on a subset (12 out of 19 cTPs) for 18 LET thresholds, using standard distribution descriptors (mean, variance and skewness). The classical dose volume histogram concept was used to evaluate the and distributions within the target of all 19 cTPs at the before determined . Statistical significance of the difference between the two groups in terms of mean and volume histogram parameters was evaluated by means of (two-sided) t-test or Mann-Whitney-U-test. In addition, the minimum target coverage at the above determined was compared and validated against three other thresholds to verify its potential in differentiation between small and large volume tumors.
Results:
An of approximately was found to be a reasonable threshold to classify the two groups. At this threshold, the and were significantly larger ( ) in small CTVs. For the small tumor group, the near-minimum and median (and ) in the CTV were in average (0.31 ± 0.08) and (0.46 ± 0.06), respectively. For the large tumors, these parameters were (0.20 ± 0.01) and (0.28 ± 0.02). The difference between the two groups in terms of mean near-minimum and median ( ) was 2.7 Gy (11%) and 5.0 Gy (18%), respectively.
Conclusions:
The feasibility of high-LET-dose based evaluation was shown in this study where a lower was found in cTPs with a large tumor size. Further investigation is needed to draw clinical conclusions. The proposed methodology in this work can be utilized for future high-LET-dose based studies.
Related Concept Videos
Biological Effects of Radiation
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation I: X-ray and CT
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Isotopes and Radioisotopes
An isotope containing...
Radiation: Applications
The average...