Related Experiment Video
Updated: Jul 16, 2025

Creating Radio-cephalic Arteriovenous Fistula in the Forearm with a Modified No-Touch Technique
Published on: April 1, 2022
Native Arteriovenous Fistula Creation in Patients With Continuous Flow Left Ventricular Assist Devices: A Case Report
Fahmi A Aldhaheri1, Samer Koussayer2, Bassam Khail2
1Nephrology, Dr. Soliman Fakeeh Hospital, Jeddah, SAU.
Abstract:
Worsening of kidney function after left ventricular assist device (LVAD) implantation is common, and many patients reaching end-stage kidney disease require long-term dialysis. Permanent vascular access in a patient with LVAD remains a clinical dilemma. There is a theoretical concern about the maturation of the arteriovenous fistula in a patient with LVAD due to the absence of a pulsatile flow in these patients. We described a case of successful creation of a left brachial-cephalic AVF in a patient with continuous flow LVAD (Abbott's HeartMate 3TM), which was used for dialysis without issue.
Related Concept Videos
Hemodialysis I: Introduction
Continuous Renal Replacement Therapy