Related Experiment Video
Updated: Jul 16, 2025

High Speed Droplet-based Delivery System for Passive Pumping in Microfluidic Devices
Published on: September 2, 2009
The information variables for controlling manual transfer of liquid-filled containers
Hongge Xu1, Jian Wang1, Jing Samantha Pan2,3
1Department of Psychology, Sun Yat-sen University, Guangzhou, China.
Abstract:
It is a familiar but challenging task to manually transfer a liquid-filled container without spilling. The action requires stringent control because the dynamics of interacting with the non-rigid aqueous content is complex. In this work, we sought to discover what properties of a liquid-filled container were predictive of transfer without spilling performance. Two candidate variables were tested (Experiment 1): The distance between liquid surface and the container's rim (h) and the container's diameter (d). Participants attempted to transfer 15 containers (3 ds and 5 hs), one at a time and as fast as possible, without spilling. Kinematic analyses showed that the movement's peak velocity and the first peak acceleration were affected by h; the movement time and the frequency of acceleration change were affected by h and d in a hierarchical manner, where transfer without spilling was first affected by h and for full containers, the thick ones were moved more slowly and went through more acceleration change; for not so full containers, the container's diameter did not have any effect. Next, each of the 15 containers was compared with the other 14, and participants judged from a pair of displayed containers which one was more likely to be moved fast without spilling (Experiment 2). Perceived affordance was affected by h and d but not by whether containers were placed upright or tilted. In general, thinner and less full containers were judged as easier to be moved fast without spilling.
Related Concept Videos
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Types of Fluids
In contrast, non-Newtonian fluids do not follow Newton's law of viscosity, and...
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
Two-Compartment Open Model: IV Infusion
The model illustrates the decrease in plasma drug concentration from the central compartment with a specific equation. It shows that under steady-state conditions, the drug's input rate...
Transfer Function in Control Systems
To derive the transfer function, consider a general nth-order linear time-invariant...

