Related Experiment Video
Updated: Jul 15, 2025

An Experimental Protocol for Assessing the Performance of New Ultrasound Probes Based on CMUT Technology in Application to Brain Imaging
Published on: September 24, 2017
Thermal analysis and SNR comparison of CMUT and PZT transducers using coded excitation
Mudabbir Tufail Bhatti1, Borislav Gueorguiev Tomov1, Søren Elmin Diederichsen2
1Center for Fast Ultrasound Imaging, Technical University of Denmark, DK-2800 Lyngby, Denmark.
Abstract:
Coded excitation (CE) has the ability to enhance image quality and penetration depth by improving the signal-to-noise ratio (SNR). Their usefulness has been extensively proven in the literature, however, there are very few publications that have discussed the practicality of using CEs, as they can increase the operating temperature of a transducer beyond the safety limits. In this paper, the potential for capacitive micromachined ultrasonic transducers (CMUTs) to handle CEs is investigated and compared to a geometrically similar Lead Zirconate Titanate (PZT) probe. It is hypothesized that CMUTs are comparatively advantageous for CE and can generate CE signals more effectively while operating within the safety limits of temperature specified by the International Electrotechnical Commission (IEC). Simple chirp signals were used for excitation and the temperature of the transducer assembly was measured under two different test conditions following the IEC standards. The still air test showed that at the pulse repetition frequency of 4 kHz and a signal duration of 8μs, the PZT probe reached the safe limit of 27 °C within 3 min of acquisition, whereas the CMUT probe showed an increase of only 4-5 °C over 30 min of scan time. The phantom experiments showed that for the maximum temperature rise allowed at the object-transducer interface by the IEC, the gain in SNR possible for the CMUT probe was 13-14 dB and the increase in penetration depth was 30 mm, whereas no gain in SNR and penetration depth was achieved for the PZT probe. The peak mechanical index and the derated spatial peak temporal averaged intensity were found to be less than half the FDA limits for both probes in all cases, proving temperature to be the first limiting factor when using CE. Therefore, the CMUT has shown to be thermally more efficient than the PZT probe and a good candidate for CE imaging.
More Related Videos
07:44Characterization of Full Set Material Constants and Their Temperature Dependence for Piezoelectric Materials Using Resonant Ultrasound Spectroscopy
Published on: April 27, 2016
10:39Fabrication and Characterization of Thickness Mode Piezoelectric Devices for Atomization and Acoustofluidics
Published on: August 5, 2020
Related Concept Videos
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...