Related Experiment Video
Updated: Jul 15, 2025

Three-Dimensional Preoperative Virtual Planning in Derotational Proximal Femoral Osteotomy
Published on: February 17, 2023
Accuracy analysis of artificial intelligence-assisted three-dimensional preoperative planning in total hip
Long Wu, Xin Zhao, Zhi-Dong Lu
1Department of Orthopedics, General Hospital of Ningxia Medical University, No. 804 of Shengli South Street, Xingqing District, Yinchuan 750001, China. lpeng125lp@126.com.
Objectives:
This study aims to assess the outcome of total hip arthroplasty (THA) using artificial intelligence (AI)-assisted three-dimensional (3D) preoperative planning technology in terms of predicting prosthesis size, acetabular cup positioning, and lowerlimb length restoration.
Patients And Methods:
Between January 2020 and July 2022, a total of 161 patients (101 males, 60 females; mean age: 57.6±10.5 years; range, 31 to 80 years) who underwent primary unilateral THA were retrospectively analyzed. The patients were divided into two groups as those who were treated with AI-assisted 3D preoperative planning technology (the observation group, n=95) and patients who were treated with traditional two-dimensional (2D) X-ray template planning technology (the control group, n=66).
Results:
The accuracy of the planning was based on the consistency of the preoperative planning and intraoperative models. The difference between the observation group and the control group was statistically significant in terms of the accuracy of the preoperative planning of acetabular prostheses (54% vs. 38%, p=0.048) and femoral prostheses (64% vs. 44%, p=0.011), with both values significantly higher in the observation group. The mean inclination angle, anteversion angle, and limb length discrepancy (LLD) in the observation group were 36.85°±4.82°, 12.10°±5.33°, and 2.18±2.70 mm, respectively, while those in the control group were 35.06°±6.07°, 10.95°±5.09°, and 4.42±3.85 mm, respectively. There was a statistically significant difference between the two groups in terms of inclination angle and LLD (p<0.05 for both), but there was no significant difference in terms of anteversion angle (p>0.05). In the observation group, 86.3% (82/95) of acetabular cups were implanted within the Lewinnek safe zone (72.7% [48/66] in the control group), while 83.2% (79/95) were within the Callanan safe zone (69.7% [46/66] in the control group), with both values higher in the observation group (p<0.05).
Conclusion:
Overall, AI-assisted 3D preoperative planning is superior to traditional 2D X-ray template planning for predicting prosthesis size, and it also has the advantage in terms of acetabular cup positioning and lower-limb length restoration.
More Related Videos
07:45The Use of Mixed Reality in Custom-Made Revision Hip Arthroplasty: A First Case Report
Published on: August 4, 2022
09:51The Transition to an Anterior-Based Muscle Sparing Approach Improves Early Postoperative Function but is Associated with a Learning Curve
Published on: September 7, 2022