Related Experiment Video
Updated: Jul 15, 2025

Non-invasive Assessment of Microvascular and Endothelial Function
Published on: January 29, 2013
Arterial Blood Pressure Features of Hypertensive Patients with Typical and Atypical 460 nm Skin Fluorescence Response
Regina Pawlak-Chomicka1, Paweł Uruski1, Tomasz Krauze2
1Department of Hypertensiology, Angiology and Internal Medicine, Poznan University of Medical Sciences, 61-848 Poznan, Poland.
Abstract:
Flow-mediated skin fluorescence (FMSF) at 460 nm is a non-invasive method for assessing dynamic changes in the reduced form of nicotinamide adenine dinucleotide (NADH) and microcirculation in forearm skin under varying conditions of tissue perfusion. Typically, fluorescence increases during ischaemia, but atypical cases show a temporary signal decrease instead of a constant increase. This study aimed to explore the clinical implications of atypical FMSF patterns in patients with newly diagnosed untreated hypertension. NADH fluorescence and pulse wave analysis were performed on 65 patients. Differences in peripheral and arterial pulse pressure profiles were examined based on FMSF curve courses. Patients with atypical curve courses had significantly (p < 0.05 or lower for all) higher heart rate, peripheral and central diastolic pressure, tension time index, central rate pressure product, shorter diastole duration, and reservoir pressure-time integral. Hypertensive patients with atypical FMSF signals had less advantageous blood pressure profiles. Although the underlying factors causing these symptoms are unknown, the atypical FMSF pattern may reflect increased sympathetic stimulation and vascular resistance. The visual assessment of the FMSF curve may have important clinical implications that deserve further investigation.
More Related Videos
Related Concept Videos
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Hypertension III: Clinical Manifestations and Diagnostic Studies
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pulse
The pulse serves as a clinical...

