Related Experiment Video
Updated: Jul 15, 2025

Preparation of Aligned Steel Fiber Reinforced Cementitious Composite and Its Flexural Behavior
Published on: June 27, 2018
Influence of Fire Exposition of Fibre-Cement Boards on Their Microstructure
Krzysztof Schabowicz1, Tomasz Gorzelańczyk1, Łukasz Zawiślak1
1Faculty of Civil Engineering, Wrocław University of Science and Technology, Wybrzeże Wyspiańskiego 27, 50-370 Wrocław, Poland.
None:
The diagnostics of materials, elements and structures after fire exposure are very complicated. Researchers carrying out such diagnostics encounter difficulties at the very beginning, e.g., how to map fire conditions. In this publication, the authors focused on the analysis of the fibre-cement composite used as facade cladding. The fibre-cement boards are construction products used in civil engineering. The fibre-cement boards are characterised by two phases: the matrix phase and the dispersed phase. The analysis of fibre-cement composite was performed using non-destructive methods. The use of non-destructive methods in the future will allow for the analysis of facades after fires without the need to obtain large elements, which will significantly reduce costs while increasing safety. The aim of the work was to determine internal changes in the microstructure of fibre-cement boards after exposure to fire. The degraded samples were compared with reference samples in the evaluation of the microstructure. An analysis was performed using a scanning electron microscope, images of backscattered electrons (BSE) and maps obtained using Energy Dispersive X-ray Spectroscopy (EDX), which allowed conclusions to be drawn. The observed changes were presented in the form of photos showing changes in the composition of the plates, and they were commented on. It should be noted that fire temperatures act destructively, and a number of changes can be observed in the microstructure. The results of the work indicate that, in the future, the use of non-destructive methods will make it possible to assess the degree of degradation of the façade after a fire.
Related Concept Videos
Fiber Reinforced Concrete
Strength and Heat of Hydration
The heat of hydration for each cement compound is significant; for instance, tricalcium aluminate (C3A) and...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Microcracking in Concrete
Types of Cement I
Type I (Ordinary Portland Cement) is widely used for general construction where special properties are not required. It has moderate sulfate resistance and heat of hydration.
Type II (Modified Cement) offers moderate resistance to sulfate attack and a lower rate of heat development compared to Type I. It is suitable for structures in...
Porosity in Cement Paste
The balance of water to cement in the mix is...

