Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Multiple Pipe Systems01:21

Multiple Pipe Systems

782
Multipipe systems consist of complex configurations of interconnected pipes designed to transport fluids efficiently across intricate networks. They are essential in engineering applications requiring precise control over flow distribution, pressure, and head loss. They are categorized into series, parallel, loop, and network configurations, each distinguished by unique flow characteristics and applications.
Series Configuration
In a series configuration, fluid flows sequentially from one pipe...
782
Single Pipe Systems01:24

Single Pipe Systems

164
In pipe flow analysis, problems are typically categorized into three types — Type I, Type II, and Type III — based on the known parameters and the desired outcome. Each type of problem addresses specific engineering requirements using fluid properties, pipe characteristics, and operational conditions.
In a Type I problem, fluid properties (density and viscosity), pipe characteristics (including diameter, length, and surface roughness), and the flow rate or average velocity are...
164
Application of Pascal's Law01:03

Application of Pascal's Law

8.5K
Pascal's experimentally proven observations—that a change in pressure applied to an enclosed fluid is transmitted undiminished throughout the fluid and to the walls of its container—provide the foundations for hydraulics, one of the most important developments in modern mechanical technology.
Hydraulic systems are used to operate automotive brakes, hydraulic jacks, and numerous other mechanical systems. We can derive a relationship between the forces in a simple hydraulic system...
8.5K
Bernoulli's Principle: Applications01:17

Bernoulli's Principle: Applications

3.9K
There are many devices and situations in which fluid flows at a constant height and so can be analyzed using Bernoulli's principle. These devices include, but are not limited to, entrainment devices and fluid flow measuring devices.
Entrainment devices use a high fluid speed to create low pressures and, thus, entrain one fluid into another. Some examples of these devices are given below:
3.9K
Design Example: Forces in Sluice Gate01:11

Design Example: Forces in Sluice Gate

750
In hydraulic engineering, sluice gates are essential for managing water flow through channels, reservoirs, and irrigation systems. Sluice gates, acting as vertical barriers, regulate water by adjusting the gate's opening height, which changes the velocity and pressure of water flowing beneath the gate. Understanding the forces involved is crucial to designing sluice gates that can withstand dynamic pressure differences, especially when the gate is closed or partially open.
Key variables in...
750
Bernoulli's Equation: Problem Solving01:16

Bernoulli's Equation: Problem Solving

1.4K
A Venturi meter is essential for measuring fluid flow rates in pipelines. It utilizes the relationship between fluid velocity and pressure described by Bernoulli's equation. When installed in a sewage system, the Venturi meter accurately determines the wastewater flow rate by measuring pressure differences.
The first step is to compute the cross-sectional areas of the pipe and the Venturi throat to analyze the pressure difference indicated by the pressure gauge. Next, the continuity...
1.4K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Parathyroid carcinoma co-occurring with parathyroid adenoma and papillary thyroid carcinoma: a rare case report with comprehensive literature review.

Therapeutic advances in endocrinology and metabolism·2026
Same author

Tribocatalysis and High-Temperature Resistance Characteristics of Magnetically Responsive Lubrication Additives.

Small (Weinheim an der Bergstrasse, Germany)·2026
Same author

mJ-level 7-octave ultraflat white laser encompassing 200-25,000 nm.

Light, science & applications·2026
Same author

Ultralow-power reservoir computing based on bidirectionally operable ferroelectric capacitors with tunable time constants.

Reports on progress in physics. Physical Society (Great Britain)·2026
Same author

Soil bacterial responses to experimental warming and drought across winter wheat growth stages in the North China Plain.

Frontiers in plant science·2026
Same author

Exploration on thermal behavior of synthetic ester with antioxidant based on thermodynamic analysis and molecular simulations.

Journal of molecular modeling·2025

Related Experiment Video

Updated: Jul 15, 2025

High Speed Droplet-based Delivery System for Passive Pumping in Microfluidic Devices
10:22

High Speed Droplet-based Delivery System for Passive Pumping in Microfluidic Devices

Published on: September 2, 2009

13.9K

A Dual-Inlet Pump with a Simple Valves System.

Le Wang1,2, Junming Liu3, Xin Wang3

  • 1School of Intelligent Manufacturing and Elevator Mechanics, Huzhou Vocational & Technical College, Huzhou 313099, China.

Micromachines
|September 28, 2023
PubMed
Summary

This study introduces a novel dual-inlet piezoelectric pump to enhance flow performance. The optimized pump design achieved a maximum flow rate of 33.18 mL/min, offering potential for microfluidic applications.

Keywords:
cantilever valvemicrofluidicoutput flow performancepiezoelectric pumpstiffness optimization

More Related Videos

Author Spotlight: Integrating Computational and Experimental Approaches in Precision Oncology
07:03

Author Spotlight: Integrating Computational and Experimental Approaches in Precision Oncology

Published on: December 1, 2023

943
Protocol for Relative Hydrodynamic Assessment of Tri-leaflet Polymer Valves
11:12

Protocol for Relative Hydrodynamic Assessment of Tri-leaflet Polymer Valves

Published on: October 17, 2013

13.9K

Related Experiment Videos

Last Updated: Jul 15, 2025

High Speed Droplet-based Delivery System for Passive Pumping in Microfluidic Devices
10:22

High Speed Droplet-based Delivery System for Passive Pumping in Microfluidic Devices

Published on: September 2, 2009

13.9K
Author Spotlight: Integrating Computational and Experimental Approaches in Precision Oncology
07:03

Author Spotlight: Integrating Computational and Experimental Approaches in Precision Oncology

Published on: December 1, 2023

943
Protocol for Relative Hydrodynamic Assessment of Tri-leaflet Polymer Valves
11:12

Protocol for Relative Hydrodynamic Assessment of Tri-leaflet Polymer Valves

Published on: October 17, 2013

13.9K

Area of Science:

  • * Mechanical Engineering
  • * Microfluidics
  • * Materials Science

Background:

  • * Piezoelectric pumps with cantilever valves often exhibit deficient output flow performance.
  • * Existing designs require improvement for efficient microfluidic applications.

Purpose of the Study:

  • * To propose and analyze a novel dual-inlet piezoelectric pump with a simplified valve system.
  • * To optimize the pump's performance through valve stiffness and chamber height adjustments.

Main Methods:

  • * Finite element analysis of the piezoelectric actuator (dry and wet modes).
  • * Mechanical vibration testing to determine operating frequency.
  • * Experimental optimization of valve stiffness and pump chamber height.

Main Results:

  • * Theoretical analysis of the pump's working principle and output flow.
  • * Achieved a maximum flow rate of 33.18 mL/min at 180 Vpp and 100 Hz.
  • * Demonstrated performance improvements through iterative design optimization.

Conclusions:

  • * The proposed dual-inlet piezoelectric pump design effectively ameliorates flow deficiencies.
  • * The optimized pump shows significant potential for microfluidic systems.
  • * This work provides new insights for developing small, intelligent pumps.