Cardiac Output and Stroke Volume Assessments by Transthoracic Echocardiography and Pulse index Continuous Cardiac
Flávia K A Gomes1,2,3, Antônio A de P Fagundes2, Fábio F Amorim1,4
1Graduate Program in Health Sciences, Higher Education School of Health Sciences (ESCS), Brasília, Federal District, Brazil.
Purpose:
Bedside transthoracic echocardiography (TTEcho) is a noninvasive cardiac output (CO) monitoring method that has grown recently. However, there are questions regarding its accuracy compared to invasive methods. We aimed to evaluate the agreement and correlation of TTEcho and pulse index continuous CO (PiCCO) monitor measurements for CO and systolic volume (SV) in critically ill patients.
Methods:
This prospective experimental study included consecutive adult patients who required invasive hemodynamic monitoring admitted at an intensive care unit in the Federal District, Brazil, from January/2019 to January/2021. Correlation and agreement between SV and CO measurements by PiCCO and TTEcho were performed using the Spearman correlation and the Bland-Altman analysis.
Results:
The study enrolled 29 patients, with adequate TTEcho evaluations in all patients. There were very strong correlations between CO-TTEcho and CO-PiCCO (r = 0.845, P < .001) and SV-TTEcho and SV-PiCCO (r = 0.800, P < .001). TTEcho estimations for CO and SV were feasible within the limits of agreement in 96.6% (28/29) compared to PiCCO. The mean difference between CO-PiCCO and CO-TTEcho was 0.250 L/min (limits of agreement: -1.083 to 1.583 L/min, percentage error: 21.0%), and between SV-PiCCO and SV-TTEcho was 2.000 mL (limits of agreement: -16.960 to 20.960, percentage error: 24.3%). The reduced cardiac index (CI) measurements by TTEcho showed an accuracy of 89.7% (95% IC: 72.6%-97.8%) and an F1 score of 92.7% (95% IC: 75.0%-98.0%), considering the CI-PiCCO as the gold standard.
Conclusion:
Echocardiographic measurements of CO and SV are comparable to measurements by PiCCO. These results reinforce echocardiography as a reliable tool to evaluate hemodynamics in critically ill patients.
More Related Videos
Related Concept Videos
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...