Related Experiment Video
Updated: Jul 15, 2025

Quantification of Levator Ani Hiatus Enlargement by Magnetic Resonance Imaging in Males and Females with Pelvic Organ Prolapse
Published on: April 17, 2019
Impedance planimetry and panometry (EndoFLIP™) can replace manometry in preoperative anti-reflux surgery assessment
Vanessa N VanDruff1,2, Julia R Amundson3,4, Stephanie Joseph3
1Department of Minimally Invasive Surgery, NorthShore University HealthSystem, 2650 Ridge Avenue, GCSI Suite B665, Evanston, IL, 60201, USA. Vanessa.vandruff@uchicagomedicine.org.
Background:
Endoluminal functional impedance planimetry and panometry assesses secondary peristalsis in response to volumetric distention under sedation. We hypothesize that impedance planimetry and panometry can replace high-resolution manometry in the preoperative assessment prior to anti-reflux surgery.
Methods:
Single institution prospective data were collected from patients undergoing anti-reflux surgery between 2021 and 2023. A 16-cm functional luminal imaging probe (FLIP) assessed planimetry and panometry prior to surgery under general anesthesia at the start of each case. Panometry was recorded and esophageal contractile response was classified as normal (NCR), diminished or disordered (DDCR), or absent (ACR) in real time by a single panometry rater, blinded to preoperative HRM results. FLIP results were then compared to preoperative HRM.
Results:
Data were collected from 120 patients, 70.8% female, with mean age of 63 ± 3 years. There were 105 patients with intraoperative panometry, and 15 with panometry collected during preoperative endoscopy. There were 60 patients (50%) who had peristaltic dysfunction on HRM, of whom 57 had FLIP dysmotility (55 DDCR, 2 ACR) resulting in 95.0% sensitivity. There were 3 patients with normal secondary peristalsis on FLIP with abnormal HRM, all ineffective esophageal motility (IEM). No major motility disorder was missed by FLIP. A negative predictive value of 91.9% was calculated from 34/37 patients with normal FLIP panometry and normal HRM. Patients with normal HRM but abnormal FLIP had larger hernias compared to patients with concordant studies (7.5 ± 2.8 cm vs. 5.4 ± 3.2 cm, p = 0.043) and higher preoperative dysphagia scores (1.5 ± 0.7 vs. 1.1 ± 0.3, p = 0.021).
Conclusion:
Impedance planimetry and panometry can assess motility under general anesthesia or sedation and is highly sensitive to peristaltic dysfunction. Panometry is a novel tool that has potential to streamline and improve patient care and therefore should be considered as an alternative to HRM, especially in patients in which HRM would be inaccessible or poorly tolerated.
Related Concept Videos
Imaging Studies V: Intravenous Urography and Retrograde Pyelography
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Endoscopic Procedures V: ERCP
Patient...

