Related Experiment Video
Updated: Jul 15, 2025

A Modified Sonographic Algorithm for Image Acquisition in Life-Threatening Emergencies in the Critically Ill Newborn
Published on: April 7, 2023
Mono- and bi-plane sonographic approach for difficult accesses in the emergency department - A randomized trial
Davide Enrici Baion1, Alberto La Ferrara1, Davide Maserin1
1Emergency Department, Città della Salute e della Scienza di Torino, Molinette Hospital, 10126 Turin, Italy.
Background:
The insertion of peripheral intravenous (PIV) catheters is one of the most performed invasive procedures in acute healthcare settings. However, peripheral difficult vascular access (PDVA) is not uncommon and can lead to delays in administering essential medications. Ultrasound (US) has emerged as a valuable tool for facilitating PIV cannulation. Advancements in technology have introduced a technique known as bi-plane imaging, allowing the simultaneous display of both longitudinal and transverse views of vessels. We aimed to investigate whether the utilization of bi-plane imaging, as opposed to the single-plane approach, would yield superior results for PDVA in the emergency department (ED).
Methods:
This study was a single-center randomized controlled trial. We included adult patients admitted to the ED who required PIV cannulation. Patients were randomly assigned to undergo cannulation using either the mono-plane or bi-plane approach, both performed by skilled providers. The primary outcome of the study was to compare the first attempt success rates between the two techniques.
Results:
A total of 442 patients were enrolled, with 221 undergoing cannulation attempts using the mono-plane approach. Successful placement of a functioning PIV catheter was achieved in a single attempt for 313 out of 442 patients (70.8%). There was no significant difference in the success rates between the two study groups: 68.3% in the mono-plane group and 73.3% in the bi-plane group (p = 0.395). The median time required for a successful attempt differed between the groups, with 45 s (range 18-600) in the mono-plane group and 35 s (range 20-600) in the bi-plane group (p = 0.03).
Conclusions:
Our study confirms that US is a highly effective tool for facilitating PIV cannulation in patients with PDVA presenting to the ED. However, our investigation into the use of bi-plane imaging did not reveal a significant improvement when compared to mono-plane imaging.
More Related Videos
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Imaging Studies II: Ultrasonography
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...