Related Experiment Video
Updated: Jul 15, 2025

Roughness Impact of Piezoelectric Dental Scaler on Two Distinct Flowable Composite Filling Materials
Published on: January 10, 2025
Influence of filler types on wear and surface hardness of composite resin restorations
Fei Chen1, Lijuan Sun2, Hao Luo3
1Department of Stomatology, Beijing Tongren Hospital, Capital Medical University, Beijing, China.
Objective:
Wear and surface hardness of resin composites are of relevance from the clinical standpoint. With the incorporation of novel filler system, more studies need to be performed to investigate newly marketed resin composites. The objective of this study was to investigate the abrasive wear and surface hardness of dental restorative with different filler types.
Methods:
Nanohybrid filled Harmonize (HM) and Tetric N-Ceram (TNC), microhybrid filled Filtek Z250 (Z250), nanofilled Filtek Z350 (Z350) were included in the study. Twelve cylindrical resin composites specimens with 10 mm in diameter and 6 mm in thickness were prepared for abrasive wear test. Eight hundred cycles under 17 kg load were conducted for final wear by CW3-1 wear machine. The specimen was cleaned with an ultrasonic unit for 3 min followed with drying procedure. After measurement of weight loss and the density of specimens, the specimens were kept for measurement of surface hardness. Surface hardness was measured using a micro-hardness tester with a Vickers diamond indenter after polishing. Three specimens of each material were observed by scanning electron microscopy (SEM) after the abrasion to evaluate the morphology of the surface. Data were analyzed using one-way analysis of variance (ANOVA), followed by Tukey HSD test (α = .05).
Results:
Z250 performed the least volume wear loss (41.1 ± 2.1 mm3), as well as the hardest value (102.7 ± 2.9 HV). There was no significant difference with the volume wear loss (p = 1.000) and surface hardness (p = 0.874) of HM and TNC. SEM images of nanohybrid filled HM and TNC represented smoother surface compared with other types of resin composites.
Conclusions:
Microhybrid Z250 showed the highest wear resistance and surface hardness, nanofilled and nanohybrid resin composites may still face the insufficient of wear and surface hardness quality.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
03:02Impact of Fabrication Techniques and Polishing Procedures on Surface Roughness of Denture Base Resins
Published on: January 17, 2025
Related Concept Videos
Additives and Fillers in Concrete
The...
Abrasion Resistance of Concrete
One such test is the revolving disc test, where three plates...
Toughness and Hardness of Aggregate