Related Experiment Video
Updated: Jul 15, 2025

A Swin Transformer-Based Model for Thyroid Nodule Detection in Ultrasound Images
Published on: April 21, 2023
Latent Transformer Models for out-of-distribution detection
Mark S Graham1, Petru-Daniel Tudosiu1, Paul Wright1
1Department of Biomedical Engineering, School of Biomedical Engineering & Imaging Sciences, King's College London, London, UK.
None:
Any clinically-deployed image-processing pipeline must be robust to the full range of inputs it may be presented with. One popular approach to this challenge is to develop predictive models that can provide a measure of their uncertainty. Another approach is to use generative modelling to quantify the likelihood of inputs. Inputs with a low enough likelihood are deemed to be out-of-distribution and are not presented to the downstream predictive model. In this work, we evaluate several approaches to segmentation with uncertainty for the task of segmenting bleeds in 3D CT of the head. We show that these models can fail catastrophically when operating in the far out-of-distribution domain, often providing predictions that are both highly confident and wrong. We propose to instead perform out-of-distribution detection using the Latent Transformer Model: a VQ-GAN is used to provide a highly compressed latent representation of the input volume, and a transformer is then used to estimate the likelihood of this compressed representation of the input. We demonstrate this approach can identify images that are both far- and near- out-of-distribution, as well as provide spatial maps that highlight the regions considered to be out-of-distribution. Furthermore, we find a strong relationship between an image's likelihood and the quality of a model's segmentation on it, demonstrating that this approach is viable for filtering out unsuitable images.
More Related Videos
03:31Author Spotlight: Enhancement of Salient Object Detection for Smart Grid Applications
Published on: December 15, 2023
06:45Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
Related Concept Videos
Transformers with Off-Nominal Turns Ratios
Transformers in Distribution System
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
Equivalent Circuits for Practical Transformers
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
Energy Losses in Transformers
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
Power System Three-Phase Short Circuits
Three-Winding Transformers
In the per-unit equivalent circuit of a grounded Y-Y three-phase...