Related Experiment Video
Updated: Jul 15, 2025

Time-dependent Increase in the Network Response to the Stimulation of Neuronal Cell Cultures on Micro-electrode Arrays
Published on: May 29, 2017
Novel adaptive synchronization in finite-time and fixed-time for impulsive complex networks with semi-Markovian
Qianhua Fu1, Wenbo Jiang1, Shouming Zhong2
1School of Electrical Engineering and Electronic Information, Xihua University, Chengdu 610039, PR China.
Abstract:
This paper intensively studied the finite-time (FNT) and fixed-time (FXT) synchronization issues for complex networks (CNs) with semi-Markovian switching and impulsive effect. The impulses are assumed to be independent of the semi-Markovian switching. Firstly, a unified FNT and FXT stability criterion of impulsive dynamical system with time-varying delays is extended by comparison principle. Secondly, two novel hybrid control schemes, which are composed of adaptive gain and switching state-feedback are proposed. Thirdly, by employing Kronecker product, Lyapunov-Krasovskii functional and inequality technique, FNT and FXT synchronization criteria for impulsive CNs with semi-Markovian switching are presented in a set of low-dimensional linear matrix inequalities, and the settling times are computed respectively. Finally, simulations are given to verify the proposed adaptive FNT and FXT synchronization criteria.
Related Concept Videos
BIBO stability of continuous and discrete -time systems
To determine the BIBO stability, the convolution integral is utilized when a bounded continuous-time input is applied to a Linear Time-Invariant (LTI) system....
Linear time-invariant Systems
The input-output behavior of an LTI system can be fully defined by its response to an impulsive excitation at its input. Once this impulse response is known, the system's reaction to any other input can be...
Basic Continuous Time Signals
The unit step function, denoted u(t), is zero for negative time values and one for positive time values, exhibiting a discontinuity at t=0. This function often represents abrupt changes, such as the step voltage introduced when turning a car's...
Entropy Change in Reversible Processes
The statement can be further generalized to prove that entropy is a state function. Take a cyclic process between any two points on a p-V diagram.
Current Growth And Decay In RL Circuits
Transient and Steady-state Response
These test signals are integral in designing control systems to exhibit two key performance aspects: transient response and steady-state...