Related Experiment Video
Updated: Jul 15, 2025

Effective Analysis of Human Exposure Conditions with Body-worn Dosimeters in the 2.4 GHz Band
Published on: May 2, 2018
Is It Appropriate to Completely Eliminate Contact Shielding during CT Examination? A Discourse Based on Experimental
Jiwei Chen1, Jianchun Tu2, Shengyan Huang3
1Department of Medical Engineering, Kunshan Hospital of Traditional Chinese Medicine, Kunshan, Jiangsu 215300, P.R. China.
Objective:
Through the integration of experimental data and literature, this study examines whether complete elimination of contact shielding during CT examination is warranted, with a particular focus on potential impacts to children's thyroid and pregnant women, as well as limitations associated with contact shielding. Methods: The thermoluminescent dosimeter (TLD) tablets were inserted into the phantom's five organs and tissues. Select fixed exposure, automatic exposure control (AEC), and use contact shielding combined into four experimental modes, with scanning of the phantom's four parts. Obtain the absorbed dose measurements within or outside the FOV. Statistical analysis was conducted using SPSS software. Results: (1) The AEC significantly reduces dose within and outside the FOV, with a dose reduction of 40%-60%. (2) The application of contact shielding outside the FOV significantly reduced the dose adjoin the FOV. (3) Both the use of AEC mode and contact shielding can effectively minimize the dose, with a reduction of 50-80%. (4) The shielding within the FOV may introduce image artifacts or interfere with AEC, the implementation of contact shielding outside FOV provides little reduction in radiation exposure risk through previous literature. (5) Contact shielding exhibits certain drawbacks in all aspects. Conclusion: The utilization of AEC mode in clinical CT should be widely adopted to minimize patient radiation exposure. In general, contact shielding both inside and outside the FOV should be avoided during exposure. However for children under 12 years old with thyroid gland examination, contact shielding could maximally reduce external radiation and may be appropriate. Pregnant women require careful evaluation when considering the use of contact shielding. Contact shielding should not be entirely abandoned.
More Related Videos
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...

