OCT based corneal densitometry: the confounding effect of epithelial speckle
Maria Miażdżyk1, Alejandra Consejo2,3, D Robert Iskander1
1Department of Biomedical Engineering, Wroclaw University of Science and Technology, Wybrzeze Wyspianskiego 27, 50-370 Wroclaw, Poland.
Biomedical Optics Express
|October 6, 2023
Summary
The corneal epithelium significantly impacts optical coherence tomography (OCT) densitometry measurements of corneal stroma transparency. Ignoring epithelial integrity can lead to over 20% estimation errors in stromal densitometry, particularly in the anterior stroma.
Area of Science:
- Ophthalmology
- Biomedical Optics
- Corneal Imaging
Background:
- Corneal densitometry objectively assesses stromal transparency, with Scheimpflug technology being dominant.
- Optical coherence tomography (OCT) offers an alternative for corneal densitometry by analyzing corneal speckle statistics.
- The influence of the overlying epithelium on in-vivo stromal densitometry measurements using OCT remains unquantified.
Purpose of the Study:
- To quantify the impact of corneal epithelial integrity on OCT-derived stromal densitometry.
- To determine the potential estimation errors introduced by the epithelium in OCT densitometry analysis.
Main Methods:
- Utilized OCT imaging on eleven porcine eyes before and after epithelial debridement.
- Analyzed corneal densitometry at various stromal depths using four distinct speckle statistics metrics.
Main Results:
- Statistically significant differences in speckle statistics were observed based on the presence or absence of the epithelium.
- Estimation errors in stromal densitometry metrics could exceed 20%, varying with stromal depth.
- Anterior stromal densitometry values were most sensitive to changes in epithelial integrity.
Conclusions:
- Epithelial integrity is a critical confounding factor for absolute OCT densitometry measurements of the corneal stroma.
- Accurate stromal densitometry analysis using OCT necessitates accounting for the epithelial layer's influence.