Related Experiment Video
Updated: Jul 14, 2025

Point-Of-Care Ultrasound Screening for Proximal Lower Extremity Deep Venous Thrombosis
Published on: February 10, 2023
Prospective Evaluation of Venous Excess Ultrasound for Estimation of Venous Congestion
August Longino1, Katie Martin2, Katarina Leyba1
1Department of Internal Medicine, University of Colorado Hospital, Aurora.
Background:
Venous excess ultrasound (VExUS) is a novel ultrasound technique previously reported as a noninvasive measure of venous congestion and predictor of cardiorenal acute kidney injury.
Research Question:
Are there associations between VExUS grade and cardiac pressures measured by right heart catheterization (RHC) and cardiac biomarkers and clinical outcomes in patients undergoing RHC?
Study Design And Methods:
We conducted a prospective cohort study at the Denver Health Medical Center from December 20, 2022, to March 25, 2023. All patients undergoing RHC underwent a blinded VExUS assessment prior to their procedure. Multivariable regressions were conducted to assess relationships between VExUS grade and cardiac pressures, biomarkers, and changes in weight among patients with heart failure, a proxy for diuretic success. Receiver operating characteristic curve and area under the curve (AUC) were derived for VExUS, inferior vena cava (IVC) diameter, and IVC collapsibility index (ICI) to predict right atrial pressure (RAP) > 10 and < 7 mm Hg.
Results:
Among 81 patients, 45 of whom were inpatients, after adjusting for age, sex, and Charlson Comorbidity Index, there were significant relationships between VexUS grade of 2 (β = 4.8; 95% CI, 2.6-7.1; P < .01) and 3 (β = 11; 95% CI, 8.9-14; P < .01) and RAP, VExUS grade of 2 (β = 6.8; 95% CI, 0.16-13; P = .045) and 3 (β = 15; 95% CI, 7.3-22; P < .01) and mean pulmonary artery pressure, and VExUS grade of 2 (β = 7.0; 95% CI, 3.9-10; P < .01) and 3 (β = 13; 95% CI, 9.5-17; P < .01) and pulmonary capillary wedge pressure. AUC values for VExUS, IVC diameter, and ICI as predictors of RAP > 10 mm Hg were 0.9 (95% CI, 0.83-0.97), 0.77 (95% CI, 0.68-0.88), and 0.65 (95% CI, 0.52-0.78), respectively. AUC values for VExUS, IVC diameter, and ICI as predictors of RAP < 7 mm Hg were 0.79 (95% CI, 0.70-0.87), 0.74 (95% CI, 0.64-0.84), and 0.62 (95% CI, 0.49-0.76), respectively. In a subset of 23 patients with heart failure undergoing diuresis, there was a significant association between VExUS grade 3 and change in weight between time of RHC and discharge (P = .025).
Interpretation:
Although more research is required, VExUS has the potential to increase diagnostic and therapeutic capabilities of physicians at the bedside and increase our understanding of the underappreciated problem of venous congestion.
Related Concept Videos
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Venous Return
What is Venous Return?
Venous return refers to the rate at which blood flows back to the heart from the body's peripheral veins. It's an integral part of the circulatory system...
Varicose Veins II: Diagnostic Studies and Interprofessional Care
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Venous Thrombosis IV: Nursing Management