Normal values of sudomotor function assessed by electrochemical skin conductance in African population
1INSERM, Université de Limoges, CHU de Limoges, EpiMaCT - Epidemiology of chronic diseases in tropical zone, Institute of Epidemiology and Tropical Neurology, OmegaHealth, Limoges, France.
Background:
Dysfunction of small nerve fibers remains a major public health concern. Subjects suspected of having small nerve fiber damage need to undergo reliable tests to confirm the diagnosis. Sudomotor function test is a reliable noninvasive exploration for detecting peripheral neuropathies. Nevertheless, the normal reference values derived from the sudomotor function test are not known in the African population. The objective of this study was therefore to describe the normal values of Electrochemical Skin Conductance (ESC) measured by the sudomotor function test in healthy African subjects.
Materials And Methods:
Between December 1st, 2021 and May 31st, 2022, ESC was measured in 475 healthy subjects (median age: 42 [31-53] years, 46% men) using a sudomotor function test, in the hands and feet. Investigators proposed the examination and received participants' consent; demographic, anthropometric, biological, and clinical data were obtained before the test. Data on 475 healthy study participants who underwent sudomotor function testing was collected and analyzed. The sociodemographic (age, sex), anthropometric (weight, height, waist circumference, body mass index), diastolic blood pressure, systolic blood pressure, heart rate, and electrochemical skin conductances of the hands and feet were assessed.
Results:
ESC values were statistically higher in men compared to women (right hand ESC: 70 [60-78] versus 63 [53-72], left hand ESC: 72 [61-80] versus 68 [57-75], right foot ESC: 77 [82-99] versus 72 [64-79], ESC left foot: 76 [68-82] versus 72 [62-78] respectively). ESC values were significantly inversely correlated with age (right hand ESC: r=-0.12, P=0.006; left hand ESC: r=-0.11, P=0.01; right foot ESC: r=-0.37, P<0.0001; ESC left foot: r=-0.38, P<0.0001). ESC values measured in feet were significantly inversely correlated with body mass index (right foot r=-0.22, P<0.0001; left foot r=-0.21, P<0.0001).
Conclusion:
This study reports normal reference values for ESCs according to age and gender in the healthy African population. Progressive decrease in ESC with aging is confirmed by our data. The value of ESC seems lower in the African population than in other reported ethnicities. This finding needs to be further explored in additional studies.
More Related Videos
10:03Conformable Wearable Electrodes: From Fabrication to Electrophysiological Assessment
Published on: July 22, 2022
06:39Electroencephalographic, Heart Rate, and Galvanic Skin Response Assessment for an Advertising Perception Study: Application to Antismoking Public Service Announcements
Published on: August 28, 2017
Related Concept Videos
Electrical Conductivity
In a practical conductor, an applied electric field may be sustained, causing a flow of electrons, which produce a current. The differential form of the current, the current density, is related to the electric field.
More generally, it is related to the force per unit charge, which involves the...
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Sensory Functions of the Skin
There are two main categories of receptors on the skin: capsulated and non-capsulated. The non-capsulated ones are mainly the pain receptors. The capsulated ones can be further categorized based on the...
Potentiometry: Membrane Electrodes