Related Experiment Video
Updated: Jul 14, 2025

07:24
A Precision Medicine Tool for Measurement and Monitoring of Hemoglobin S in Sickle Cell Disease Patients Receiving Transfusion Therapy
1.7K
A diagnostic electrochemical aptasensor development for sCD80 protein detection in human serum
Abeer K Malkawi1, Maziar Jafari1, Leanne Ohlund1
1Department of Chemistry, Université Du Québec à Montréal, Montreal, QC, H3C 3P8, Canada.
Biosensors & Bioelectronics
|October 10, 2023
Summary
A new aptasensor detects soluble CD80 (sCD80), a biomarker for rheumatoid arthritis (RA). This biosensor offers a sensitive and specific alternative to traditional immunoassays for improved RA diagnosis.
Area of Science:
- Biomedical Engineering
- Biosensor Technology
- Analytical Chemistry
Background:
- Elevated soluble CD80 (sCD80) levels in serum are linked to autoimmune diseases like rheumatoid arthritis (RA), indicating its potential as a diagnostic biomarker.
- Current methods for sCD80 detection, such as immunoassays, suffer from drawbacks including cross-reactivity, necessitating the development of more accurate detection techniques.
Purpose of the Study:
- To develop and validate a novel aptamer-based biosensor (aptasensor) for the sensitive and specific detection of sCD80.
- To establish a label-free electrochemical detection platform for sCD80 quantification in biological samples.
Main Methods:
- Selection of a high-affinity DNA aptamer for sCD80 using the SELEX process (Kd = 47.69 nM).
- Development of a label-free aptasensor on a screen-printed gold electrode (AuSPE) platform utilizing electrochemical impedance spectroscopy (EIS).
- Characterization of aptamer immobilization and sCD80 binding using photo-induced force microscopy (PIFM).
Main Results:
- The aptasensor demonstrated a linear detection range from 0.025 to 10.0 nM for sCD80, with a low limit of detection (LOD) of 8.0 pM.
- The sensor exhibited high performance in a biological matrix, showing a linear response to spiked sCD80 with R2 = 0.9887.
- Accurate recovery (105-125%) and low coefficient of variation (<7%) confirmed the aptasensor's reliability for detecting sCD80 in complex samples.
Conclusions:
- A novel, sensitive, and specific aptasensor for sCD80 detection has been successfully developed on an AuSPE platform.
- The aptasensor offers a promising label-free electrochemical method for sCD80 quantification, overcoming limitations of traditional immunoassays.
- This aptasensor holds significant potential for the early diagnosis and monitoring of RA and other autoimmune diseases.