Related Experiment Video
Updated: Jul 14, 2025

An Anaerobic Biosensor Assay for the Detection of Mercury and Cadmium
Published on: December 17, 2018
A Semi-Automatic Environmental Monitoring Device for Mercury and Cobalt Ion Detection
Yi-Ru Chiou1,2,3, Hao-Ming Pang1, Yu-Fen Huang3,4
1Institute of Applied Mechanics, National Taiwan University, Taipei, 106, Taiwan.
Abstract:
A syringe-based, semi-automatic environmental monitoring device is developed for on-site detection of harmful heavy metal ions in water. This portable device consists of a spring-embedded syringe and a polydimethylsiloxane (PDMS) membrane-based flow regulator for semi-automatic fix-and-release fluidic valve actuation, and a paper-based analytical device (PAD) with two kinds of gold nanoclusters (AuNCs) for sensitive Hg2+ and Co2+ ion detection, respectively. The thickness of the elastic PDMS membrane can be adjusted to stabilize and modulate the flow rates generated by the pushing force provided by the spring attached to the plunger. Also, different spring constants can drastically alter the response time. People of all ages can extract the fix-volume sample solutions and then release them to automatically complete the detection process, ensuring high reliability and repeatability. The PAD comprises two layers of modified paper, and each layer is immobilized with bovine serum albumin-capped gold nanoclusters (R-AuNCs) and glutathione-capped gold clusters (G-AuNCs), respectively. The ligands functionalized on the surface of the AuNCs not only can fine-tune the optical properties of the nanoclusters but also enable specific and simultaneous detection of Hg2+ and Co2+ ions via metallophilic Au+ -Hg2+ interaction and the Co2+ -thiol complexation effect, respectively. The feasibility of the device for detecting heavy metal ions at low concentrations in various environmental water samples is demonstrated. The Hg2+ and Co2+ ions can be seen simultaneously within 20 min with detection limits as low as 1.76 nm and 0.27 µm, respectively, lower than those of the regulatory restrictions on water by the US Environmental Protection Agency and the European Union. we expect this sensitive, selective, portable, and easy-to-use device to be valid for on-site multiple heavy metal ion pollution screenings in resource-constrained settings.
More Related Videos
10:31Detection and Recovery of Palladium, Gold and Cobalt Metals from the Urban Mine Using Novel Sensors/Adsorbents Designated with Nanoscale Wagon-wheel-shaped Pores
Published on: December 6, 2015
04:09Demonstrating the Simplicity and In Situ Temperature Monitoring of the Mechanochemical Synthesis of Metal Chalcogenides Suitable for Thermoelectrics
Published on: August 30, 2024
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
High-Performance Liquid Chromatography: Types of Detectors
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Atomic Emission Spectroscopy: Instrumentation
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...