EURADOS intercomparisons on whole-body dosemeters for photons from 2008 to 2020: analysis and comparison of general
Hannes Stadtmann1, Markus Figel2, Tom Grimbergen3
1Seibersdorf Labor GmbH, Radiation Protection Dosimetry, A-2444 Seibersdorf, Austria.
Abstract:
Starting in 2008 the European Dosimetry Group (EURADOS) has been performing international intercomparisons (ICs) on photon whole-body dosemeters for individual monitoring services. These ICs have been organized (on a biennial basis) starting 2008 up to 2020 now, each time with a similar set-up but with small alterations in the subsequent irradiation plans. The response for Hp(10) and Hp(0.07) was tested for different radiation qualities, angles of incidences (0°-60°) within a wide range of dose values (0.5-500 mSv), to check energy and angular response, linearity, reproducibility and mixed-field response. Within the last 12 years almost 15 000 whole body dosemeters have been irradiated and the corresponding response values evaluated. With an increasing number of participants and participating systems (from 62 to 132), this IC program has become an important tool for individual monitoring services to test their whole-body dosimetry systems, compare their results with other services or systems and to improve the quality of their dosimetry. The paper presents and compares the general results of these seven ICs and analyses the dosimetric results for the participating system types.
More Related Videos
Related Concept Videos
Biological Effects of Radiation
Absorption of Radiation
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...