Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Phase Contrast and Differential Interference Contrast Microscopy01:26

Phase Contrast and Differential Interference Contrast Microscopy

8.2K
Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
8.2K
X-ray Imaging01:24

X-ray Imaging

5.6K
German physicist Wilhelm Röntgen (1845–1923) was experimenting with electrical current when he discovered that a mysterious and invisible "ray" would pass through his flesh but leave an outline of his bones on a screen coated with a metal compound. In 1895, Röntgen made the first durable record of the internal parts of a living human: an "X-ray" image (as it came to be called) of his wife’s hand. Scientists worldwide quickly began their own experiments with...
5.6K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Paired CycleGAN-based virtual staining for 3D X-ray histology of bone-implant systems.

Journal of synchrotron radiation·2026
Same author

Synchrotron radiation micro-computed tomography of the small-spotted catshark embryonic development (Chondrichthyes: Scyliorhinus canicula).

GigaScience·2026
Same author

Directional dark field for nanoscale full-field transmission X-ray microscopy.

Light, science & applications·2026
Same author

Developmental dynamics of catshark cranial neural crest cells provide insights into gnathostome facial evolution.

Development (Cambridge, England)·2026
Same author

The About 100 Million Years Old Enigmatic "Beak Larva" Is a Weird Click Beetle Relative.

Insects·2026
Same author

Extending the Field of View in Modulation-Based X-Ray Phase Microtomography.

IEEE transactions on image processing : a publication of the IEEE Signal Processing Society·2026

Related Experiment Video

Updated: Jul 13, 2025

Measurement of X-ray Beam Coherence along Multiple Directions Using 2-D Checkerboard Phase Grating
10:39

Measurement of X-ray Beam Coherence along Multiple Directions Using 2-D Checkerboard Phase Grating

Published on: October 11, 2016

9.7K

High-resolution and sensitivity bi-directional x-ray phase contrast imaging using 2D Talbot array illuminators.

Alex Gustschin1, Mirko Riedel1,2, Kirsten Taphorn1

  • 1Department of Physics and Munich School of Bioengineering, Technical University of Munich, 85748, Garching, Germany.

Optica
|October 13, 2023
PubMed
Summary
This summary is machine-generated.

Two-dimensional Talbot array illuminators achieve high-resolution x-ray phase imaging of soft tissues. This new method enables detailed 3D imaging for applications like virtual histology.

More Related Videos

High Spatial Resolution Chemical Imaging of Implant-Associated Infections with X-ray Excited Luminescence Chemical Imaging Through Tissue
07:48

High Spatial Resolution Chemical Imaging of Implant-Associated Infections with X-ray Excited Luminescence Chemical Imaging Through Tissue

Published on: September 30, 2022

1.3K
A TIRF Microscopy Technique for Real-time, Simultaneous Imaging of the TCR and its Associated Signaling Proteins
16:10

A TIRF Microscopy Technique for Real-time, Simultaneous Imaging of the TCR and its Associated Signaling Proteins

Published on: March 22, 2012

23.9K

Related Experiment Videos

Last Updated: Jul 13, 2025

Measurement of X-ray Beam Coherence along Multiple Directions Using 2-D Checkerboard Phase Grating
10:39

Measurement of X-ray Beam Coherence along Multiple Directions Using 2-D Checkerboard Phase Grating

Published on: October 11, 2016

9.7K
High Spatial Resolution Chemical Imaging of Implant-Associated Infections with X-ray Excited Luminescence Chemical Imaging Through Tissue
07:48

High Spatial Resolution Chemical Imaging of Implant-Associated Infections with X-ray Excited Luminescence Chemical Imaging Through Tissue

Published on: September 30, 2022

1.3K
A TIRF Microscopy Technique for Real-time, Simultaneous Imaging of the TCR and its Associated Signaling Proteins
16:10

A TIRF Microscopy Technique for Real-time, Simultaneous Imaging of the TCR and its Associated Signaling Proteins

Published on: March 22, 2012

23.9K

Area of Science:

  • X-ray optics and imaging
  • Phase contrast imaging
  • Soft tissue characterization

Background:

  • Development of advanced wavefront modulators for X-ray applications.
  • Need for high-resolution, high-contrast imaging techniques for soft tissues.
  • Limitations of existing wavefront markers in X-ray phase imaging.

Purpose of the Study:

  • To design, fabricate, and evaluate 2D Talbot array illuminators (TAIs) for X-ray phase imaging.
  • To demonstrate differential X-ray phase contrast and dark-field imaging with TAIs.
  • To apply the developed method for high-resolution X-ray phase computed tomography.

Main Methods:

  • Design and fabrication of 2D TAIs for X-ray phase contrast.
  • Implementation of a 1D linear phase stepping approach for 2D phase sensitivity.
  • Utilizing unified modulated pattern analysis (UMPA) for phase retrieval.
  • Performance comparison with other wavefront markers (period, visibility, flux efficiency).

Main Results:

  • TAIs demonstrated high compression ratio intensity modulations at micrometer scale.
  • Successful demonstration of differential X-ray phase contrast and dark-field imaging.
  • Achieved 3 µm resolution in X-ray phase computed tomography of an unstained murine artery.
  • TAIs showed flexibility for limited beam coherence and detector resolution.

Conclusions:

  • 2D TAIs are effective for high-resolution, high-contrast X-ray phase imaging of soft tissues.
  • The UMPA method enables quantitative 3D imaging of soft matter, offering virtual histology possibilities.
  • TAIs present potential for diverse X-ray applications including dynamic imaging and microscopy.