Related Experiment Video
Updated: Jul 13, 2025

Emergency Undocking in Robotic Surgery: A Simulation Curriculum
Published on: May 20, 2018
Dual docking technique for robotic repair of simultaneous inguinal and umbilical hernia: A preliminary single center
Pietro Anoldo1, Michele Manigrasso1, Anna D'Amore2
1Department of Advanced Biomedical Sciences, Federico II University of Naples, Naples, Italy.
Background:
This study aimed to assess clinical results in terms of intraoperative outcomes, recovery and recurrence of our robotic technique for the treatment of patients affected by simultaneous inguinal and umbilical hernia, providing technical details to facilitate multiquadrant surgery in robotic hernia repair.
Methods:
Data from patients affected by simultaneous primary inguinal and umbilical hernia who underwent robotic repair with our dual docking technique was retrospectively analysed.
Results:
Fifteen patients were included. No intraoperative complications occurred. All patients achieved complete mobilisation within 7 h. The mean length of hospital stay was 21.6 h, with five patients discharged on the same day of surgery. There was no major complication and no recurrence within the median follow-up period of 673 days.
Conclusions:
This surgical technique shows optimal postoperative outcomes, such as early mobilisation and short length of stay. Our study provides an aid to surgeons performing multiquadrant robotic surgery for the treatment of abdominal hernias.