Related Experiment Video
Updated: Jul 13, 2025

Image-guided Convection-enhanced Delivery into Agarose Gel Models of the Brain
Published on: May 14, 2014
A Biphasic Fluid-Structure Interaction Model of Backflow During Infusion Into Agarose Gel
Arthur D Ayers1, Joshua H Smith1
1Department of Mechanical Engineering, Lafayette College, Easton, PA 18042.
Abstract:
The efficacy of convection-enhanced delivery as a technique to treat disorders of the central nervous system is limited by backflow, in which the infused fluid flows backward along surface of the catheter rather than toward the targeted area. In order to improve treatment protocols, finite element models of backflow have been developed to understand the underlying physics. García et al. (2013, "Description and Validation of a Finite Element Model of Backflow During Infusion Into a Brain Tissue Phantom," ASME J. Comput. Nonlinear Dyn., 8(1), p. 011017) presented a finite element model that accounted for the flow in the annular gap that develops between the tissue and the outer surface of the catheter by using a layer of biphasic elements with a formula for the axial hydraulic conductivity to represent annular Poiseuille flow. In this study, we present a generalization of that model using fluid-FSI and biphasic-FSI elements that are recently available in febio. We demonstrate that our model of a 0.98 mm radius catheter is able to reproduce experimental backflow lengths and maximum fluid pressures for infusions into a brain tissue surrogate and that it agrees well with the previous model by García et al. (2013, "Description and Validation of a Finite Element Model of Backflow During Infusion Into a Brain Tissue Phantom," ASME J. Comput. Nonlinear Dyn., 8(1), p. 011017). The model predicts that the backflow length and the total amount of flow into the hemispherical region forward of the catheter tip is comparable for two different catheter sizes, albeit at a higher fluid pressure for the smaller catheter. This biphasic-FSI model has the potential to be extended to a stepped catheter geometry, which has been shown in experiments to be successful in controlling backflow.
Related Concept Videos
Two-Compartment Open Model: IV Infusion
The model illustrates the decrease in plasma drug concentration from the central compartment with a specific equation. It shows that under steady-state conditions, the drug's input rate...
One-Compartment Model: IV Infusion
The one-compartment model for IV infusion uses mathematical equations to describe the rate of change in drug quantity in the body. At steady-state or infusion equilibrium, the drug input...

