Related Experiment Video
Updated: Jul 13, 2025

Author Spotlight: Characterizing Porous Materials for Aiding the Development of Robust Metal-Organic Frameworks with Adsorption Behavior
Published on: March 8, 2024
Metal-organic frameworks as solid-phase microextraction adsorbents for the determination of triacetone triperoxide by
Weiya Xie1, Xiaohan Zhu1, Hongcheng Mei2
1Peoples' Public Security University of China, PR China; Insititute of Forensic Science, Ministry of Public Security, PR China.
Abstract:
Triacetone triperoxide (TATP) is a high-power explosive which is often used by criminals. The detection of TATP is of great significance for solving the explosion cases. However, the preconcentration and analysis of trace levels of TATP still pose challenges for analytical researchers. In this study, metal-organic frameworks (MOFs), including IRMOF-8, MOF-5, UIO-66, ZIF-8, and MIL-101(Cr), were immobilized on a stainless steel wire using a physical adhesive method as a solid-phase microextraction (SPME) fiber coating. The prepared fibers with a controllable thickness were used for the extraction of TATP followed by gas chromatography-mass spectrometry (GC-MS) analysis. Under the identical experimental conditions, the IRMOF-8-coated fiber exhibited higher extraction efficiency for TATP than the other fibers. The IRMOF-8-coated fiber was then characterized using scanning electron microscopy and thermogravimetric analysis. The results indicated that the IRMOF-8-coated fiber not only had good thermal and chemical stabilities but also afforded a high TATP extraction efficiency. Under the same extraction conditions, the extraction efficiency of the IRMOF-8-coated fiber was 2-8 times higher than those of commercial fibers. The limit of detection was 13 ng/mL, and linearity was observed in the range of 50-5000 ng/mL with a correlation coefficient greater than 0.998. The intraday repeatability (n = 6), interday repeatability (n = 3), and fiber-to-fiber reproducibility (n = 3), were 4.1 %, 4.8 %, and 8.0 %, respectively. The recoveries of TATP from the simulated tap water and soil samples were 87.32-90.57 % and 88.76-100.93 %, respectively, with relative standard deviations lower than 11.11 % (n = 3). The above method was successfully applied for the detection of TATP transferred from a finger to a paper surface, demonstrating its good application prospects in the analysis of trace TATP.
More Related Videos
11:38In situ FTIR Spectroscopy as a Tool for Investigation of Gas/Solid Interaction: Water-Enhanced CO2 Adsorption in UiO-66 Metal-Organic Framework
Published on: February 1, 2020
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Extraction: Advanced Methods
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...