Related Experiment Video
Updated: Jul 13, 2025

Generation of Electronic Cigarette Aerosol by a Third-Generation Machine-Vaping Device: Application to Toxicological Studies
Published on: August 25, 2018
Helping pregnant smokers quit: a multi-centre randomised controlled trial of electronic cigarettes versus nicotine
Dunja Przulj1, Francesca Pesola1, Katie Myers Smith1
1Wolfson Institute of Population Health, Queen Mary University of London, London, UK.
Background:
Some pregnant smokers try e-cigarettes, but effectiveness and safety of such use are unknown.
Objectives:
To compare effectiveness and safety of nicotine patches and e-cigarettes in pregnancy.
Design:
A pragmatic multi-centre randomised controlled trial.
Setting:
Twenty-three hospitals across England, and a Stop Smoking Service in Scotland.
Participants:
One thousand one hundred and forty pregnant daily smokers (12-24 weeks' gestation) motivated to stop smoking, with no strong preference for using nicotine patches or e-cigarettes.
Interventions:
Participants in the e-cigarette arm were posted a refillable e-cigarette device with two 10 ml bottles of tobacco-flavoured e-liquid (18 mg nicotine). Participants in the nicotine patches arm were posted a 2-week supply of 15 mg/16-hour nicotine patches. Supplies were provided for up to 8 weeks. Participants sourced further supplies themselves as needed. Participants in both arms received support calls prior to their target quit date, on the quit date, and weekly for the next 4 weeks.
Outcome Measures:
The primary outcome was validated prolonged abstinence at the end of pregnancy. Participants lost to follow-up or not providing biochemical validation were included as non-abstainers. Secondary outcomes included self-reported abstinence at different time points, treatment adherence and safety outcomes.
Results:
Only 55% of self-reported abstainers mailed back useable saliva samples. Due to this, validated sustained abstinence rates were low (6.8% vs. 4.4% in the e-cigarettes and nicotine patches arms, respectively, risk ratio = 1.55, 95% confidence interval 0.95 to 2.53; Bayes factor = 2.7). In a pre-specified sensitivity analysis that excluded abstainers using non-allocated products, the difference became significant (6.8% vs. 3.6%, risk ratio = 1.93, 95% confidence interval 1.14 to 3.26; Bayes factor = 10). Almost a third of the sample did not set a target quit date and the uptake of support calls was low, as was the initial product use. At end of pregnancy, 33.8% versus 5.6% of participants were using their allocated product in the e-cigarettes versus nicotine patches arm (risk ratio = 6.01, 95% confidence interval 4.21 to 8.58). Regular use of e-cigarettes in the nicotine patches arm was more common than use of nicotine replacement products in the e-cigarette arm (17.8% vs. 2.8%). Rates of adverse events and adverse birth outcomes were similar in the two study arms, apart from participants in the e-cigarette arm having fewer infants with low birthweight (<2500 g) (9.6% vs. 14.8%, risk ratio = 0.65, 95% confidence interval 0.47 to 0.90; Bayes factor = 10.3).
Limitations:
Low rates of validation reduced the study power. A substantial proportion of participants did not use the support on offer sufficiently to test its benefits. Sample size may have been too small to detect differences in less frequent adverse effects.
Conclusions:
E-cigarettes were not significantly more effective than nicotine patches in the primary analysis, but when e-cigarettes use in the nicotine patches arm was accounted for, e-cigarettes were almost twice as effective as patches in all abstinence outcomes. In pregnant smokers seeking help, compared to nicotine patches, e-cigarettes are probably more effective, do not pose more risks to birth outcomes assessed in this study and may reduce the incidence of low birthweight.
Future Work:
Routine monitoring of smoking cessation and birth outcomes in pregnant women using nicotine patches and e-cigarettes and further studies are needed to confirm these results.
Trial Registration:
This trial is registered as ISRCTN62025374 and Eudract 2017-001237-65.
Funding:
This project was funded by the National Institute for Health and Care Research (NIHR) Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 27, No. 13. See the NIHR Journals Library website for further project information.
More Related Videos
10:44Comparing the Effects of Electronic Cigarette Vapor and Cigarette Smoke in a Novel In Vivo Exposure System
Published on: May 24, 2017
09:30A Microcontroller Operated Device for the Generation of Liquid Extracts from Conventional Cigarette Smoke and Electronic Cigarette Aerosol
Published on: January 18, 2018
Related Concept Videos
Stimulants
Cocaine can be administered via snorting, injection, or smoking. It primarily functions by blocking the reuptake of dopamine, resulting in a euphoric high characterized by an intense sensation of happiness and...
Drugs Acting on Autonomic Ganglia: Stimulants
Ganglionic stimulants activate NM nicotinic receptors in autonomic ganglia, falling into two categories: nicotine mimetics [e.g., lobeline, dimethylpiperazine, tetramethylammonium] and muscarinic receptor agonists [e.g., muscarine, methacholine]. The first category's action is rapid and blocked by nicotinic receptor antagonists, while the second category's action is delayed and blocked by atropine-like agents. Nicotine, an alkaloid, affects the heart rate by stimulating...
Statistical Methods for Analyzing Epidemiological Data
Upper Respiratory Drugs: Antitussives, Expectorants, and Mucolytics
Antitussives include codeine, dextromethorphan (Robitussin), and benzonatate (Tessalon). Codeine and dextromethorphan exert their effects centrally by suppressing the cough reflex center in the medulla. Benzonatate operates peripherally within the respiratory tract by...
Drug Dependence
CNS Depressants: Alcohol and Nicotine