Related Experiment Video
Updated: Jul 12, 2025

High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
Stress-only dynamic computed tomography perfusion protocol (CTP) alone without computed tomography coronary
Olga Sliwicka1, Andrea Baggiano2, Ioannis Sechopoulos3
1Department of Medical Imaging, Radboud University Medical Center, Nijmegen, the Netherlands.
Purpose:
To investigate diagnostic performance of stress-only dynamic myocardial computed tomography perfusion (CTP) without computed tomography coronary angiography (CCTA) to diagnose ischemia with invasive fractional flow reserve (FFR) as a reference standard.
Method:
135 datasets (68 positive for ischemia with invasive FFR < 0.8) acquired with a 256-slice CT system (Revolution, GE Healthcare, Chicago, IL, USA) were retrieved, postprocessed with a deep learning-based algorithm (Advanced intelligent Clear-IQ Engine (AiCE), Canon Medical Systems, Otawara, Japan) (FC03/cardiac kernel, 8 mm slice thickness), analyzed using a dedicated workstation (Vitrea research 7.11.0. Vital Images, Minnetonka, MN, USA), and loaded into a clinical workstation (CardIQ, GE Healthcare, Chicago, IL, USA) for review. Ten observers with various experience from two research sites evaluated the post-processed images, perfusion slices and maps to indicate presence vs absence of perfusion defect and its probability (five-point Likert scale). Binary decisions and probability scores were used to calculate sensitivity and specificity for each reader, and to create receiver operating characteristics (ROC) curves, respectively. Furthermore, the correlation coefficient (ICC) was computed. ROC AUC of a purely quantitative analysis was obtained thanks to a color-coded map with a fixed scale superimposed on myocardial walls displaying myocardial blood flow (MBF) values.
Results:
The overall case-based sensitivity and specificity for the detection of perfusion deficit were 0.79 and 0.30, respectively. No significant differences were detected in the AUC across readers (p value = 0.66). The AUC values were 0.50, 0.58, 0.63, 0.59, 0.45, 0.60, 0.56, 0.61, 0.52, 0.61. Absolute reader agreement ICC was 0.60 (good agreement) for an average case.
Conclusion:
Dynamic CTP alone has good sensitivity, but low specificity when analyzed without CCTA. These findings reinforce the need to guide the interpretation functional test with the knowledge of coronary artery anatomy.
More Related Videos
08:13In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
10:16Retrograde Perfusion and Filling of Mouse Coronary Vasculature as Preparation for Micro Computed Tomography Imaging
Published on: February 10, 2012
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Acute Coronary Syndrome III: Diagnostic Studies
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...