Five-year trends in bacterial contamination of dialysis equipment
Eiichi Osono1,2, Kazumi Honda1, Yuki Inoue1
1Koshigaya Ohbukuro Clinic.
Abstract:
Bedside dialysis monitoring equipment for hemodialysis are located in the bioburden section upstream of the endotoxin-retentive filter for dialysis fluid sterilization. We observed 26 equipment at our institution for bacterial contamination at least once every 4 weeks for 5 years with another ultrafiltration membrane upstream to prevent bacterial contamination. Bacterial contamination levels were highest and most diverse at the time of the first flush. During subsequent initial cleanng, the contamination level decreased, and bacterial species converged almost exclusively to one genus, namely Methylobacterium spp. During clinical use, the equipment were cleaned and disinfected daily after dialysis, and daily operations and maintenance were performed using aseptic techniques. Although the frequency of bacterial detection decreased annually, the same bacterial genotypes observed at the first flush were isolated even after long time periods and were thought to persist in the equipment possibly by forming biofilm. Pseudomonas aeruginosa was newly detected after the replacement of parts during breakdown maintenance, indicating the need to sterilize replacement parts. Thus, the bioburden should be assessed regularly as part of the management of in-house-produced dialysis fluid.
Related Concept Videos
Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications
Dialysis
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Hemodialysis II: Procedure and Complications
Bacterial Signaling
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...