Related Experiment Video
Updated: Jul 12, 2025

In Vivo Quantification of Hip Arthrokinematics during Dynamic Weight-bearing Activities using Dual Fluoroscopy
Published on: July 2, 2021
The Influence of Body Mass Index on Radiation Dose and Exposure Time in Fluoroscopic Guided Hip Injections - A
Sujith Sidharthan1, Chandrashekara Maliyappa1, Hans Bhinda1
1Department of Trauma and Orthopaedics, Southend University Hospital, Mid and South Essex NHS Foundation Trust, Prittlewell Chase, Westcliff-on-Sea, Essex, SS0 0RY, United Kingdom.
Objectives:
Intra-articular hip injections (IHI) are routinely performed for both diagnostic and therapeutic purposes. The procedure can be performed via either an anterior or a lateral approach with fluoroscopic guidance being widely practised. There is a risk of radiation exposure associated with fluoroscopy assisted IHI. This may be influenced either by the surgical approach or the patient's body mass index (BMI) or both. This study was undertaken to compare the relationships of the respective approaches to BMI, fluoroscopic exposure time (FET) and radiation dose (RD).
Methods:
A retrospective study was conducted comprising 74 patients who underwent IHI with 37 patients in each group (anterior and lateral). Patients were assessed pre-operatively and post operatively for any complications. The intra-operative radiation dose, fluoroscopic exposure time and BMI data were collected and analyzed.
Results:
The mean age of the patients in anterior and lateral groups was 61.18±14.08 and 67.21±14.39 years respectively. No complications were noted in either group. However, there was a significant increase in FET (P=0.002) and RD (P<0.001) in patients with BMI ≥ 30. In the lateral group, this trend was markedly noted with increase in FET (P<0.001) and RD (P<0.001) in patients with BMI ≥ 30. On the other hand, in the anterior group there was no statistically significant increase in FET (P=0.155) and only a moderate increase in RD (P=0.020) in patients with BMI ≥ 30.
Conclusion:
Both anterior and lateral approaches to fluoroscopic guided IHI are equally safe in terms of complications involved. There is statistically significant increase in both radiation dose and fluoroscopic exposure time in patients with BMI ≥ 30. This is more pronounced in lateral approach. The anterior approach is most effective in reducing both radiation dose and fluoroscopic exposure time, more so in patients with BMI of 30 and above.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Biological Effects of Radiation
Ultrasonography
During an ultrasonography procedure, a handheld device called...
X-ray Imaging
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...