Related Experiment Video
Updated: Jul 12, 2025

Simulation of Human-induced Vibrations Based on the Characterized In-field Pedestrian Behavior
Published on: April 13, 2016
Mitigating the negative impact of new buildings on existing buildings' user comfort-a case study analysis
Vinu Subashini Rajus1, Nicolas Arellano Risopatron2, William O'Brien3
1Department of Systems and Computer Engineering, Carleton University, Canada.
Abstract:
Campus master plans are released every few years for developing and implementing its physical infrastructure. Open spaces, compactness, connectivity, greenness, and environmental impact have often been the focus on its framework. In particular, the effect of new building development on existing buildings' occupant comfort and design intent is mostly ignored. Providing guidelines to retain existing users' comfort for stakeholders involved in design decision making will result in improved design decisions. Hence, this research aims to provide a work methodology to mitigate the adverse effects of new buildings on existing buildings' user comfort through a case study at Carleton University. The case study shows a methodology to retain the existing users' comfort by analyzing Carleton University's master plan on massing studies, occupant survey to understand their comfort needs, performance analysis of the impact of the new building on the existing building user comfort. The analysis reveals the key parameters to consider in design for occupants' comfort. Finally, the research reinforces the generative design and the need for dynamic modeling in campus master plans to mitigate the negative implications of new development on occupants' comfort.
Related Concept Videos
Design Example: Sustainability in Concrete Building
There are multiple approaches to achieve sustainability in a commercial concrete building. For instance, construct a concrete parking area under the building, utilizing pervious concrete paver blocks in open areas to facilitate rainwater collection through an underground...
Thermal Insulation in Masonry Walls
External insulation can be applied using an Exterior Insulation and Finish System (EIFS), which involves affixing panels of plastic foam to the wall and covering them with a polymeric stucco reinforced with glass fiber mesh....
Types of Building Separation Joints
Volume-change joints address the effects of expansion and contraction due to temperature and moisture variations. They are strategically placed at discontinuities in a building's mass where cracking is most likely and are spaced about 150 to 200...
Movement Joints in Buildings
The simplest type of movement joints, working joints, are...
Masonry Loadbearing Walls
Expansion and Contraction in Masonry Walls
To...

