Related Experiment Video
Updated: Jul 12, 2025

A Novel Digital Platform for a Monitored Home-based Cardiac Rehabilitation Program
Published on: April 19, 2019
Patient Self-Monitoring Using Intelligent Phonocardiography on a Mobile Platform
Malin Jakobsen1, Ankica Babic1,2
1Department of Information Science and Media Studies, University of Bergen, Bergen, Norway.
Abstract:
The paper presents the design and high-fidelity prototype of the remote patient self-monitoring system using a combination of intelligent phonocardiography, mobile and web-based platforms. The advantage of self-monitoring is patient awareness about potential changes, the convenience of performing the measurement often, and the saving of the findings. A mobile platform enables a physician to see the data, get a summary of patient recordings, and as well as saving the data. We have designed two user profiles to enable such functionality and to enable consultations. During the three development iterations, two main prototypes were developed. In the patient prototype, the main functionality is measuring PCG signals, but with the possibility of reading more details about the results. In the physician's prototype, the main functionality is the patient overview, with the possibility of querying through old patient data to consult newer patients. For physicians to monitor patients monitoring themselves, the solution needs to be properly clinically validated and regulatory demands satisfy before it could be utilized in the Norwegian health domain.
More Related Videos
05:03Patient Directed Recording of a Bipolar Three-Lead Electrocardiogram using a Smartwatch with ECG Function
Published on: December 11, 2019
06:16Signal Acquisition, Score Interpretation, and Economics of a Non-Invasive Point-of-Care Test for Coronary Artery Disease
Published on: August 9, 2024
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Holter Monitor: 24-Hour Monitoring
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...