Related Experiment Video
Updated: Jul 12, 2025

Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
Customizable Scintillator of Cs3 Cu2 I5 :2% In+ @Paper for Large-Area X-Ray Imaging
Weiqing Chen1,2, Ting Wang3, Tianchi Wang2
1School of Mechanical Engineering, Institute for Advanced Materials, Chengdu University, Chengdu, 610106, P. R. China.
Abstract:
High-resolution X-ray imaging is increasingly required for medical diagnosis and large-area detection. However, the issues of scattering and optical crosstalk are limiting the spatial resolution of the indirect X-ray imaging. In this study, a feasible and efficient strategy is proposed to in situ synthesize flexible Cs3 Cu2 I5 :2%In+ @paper as a superior scintillator film, which can be scaled up to an ultra-large area of 4800 cm2 . The as-obtained Cs3 Cu2 I5 :2%In+ @paper performs a fascinating photoluminescence quantum efficiency up to 88.14%, a steady state light yield of 70169 photons/MeV, and spatial resolution of 15 lp mm-1 . Moreover, the suppressed physical scattering and optical crosstalk of the corresponding film are demonstrated. Accordingly, this work explores a feasible fabrication of customizable scintillation films with large area for high-resolution X-ray detection.
More Related Videos
07:48High Spatial Resolution Chemical Imaging of Implant-Associated Infections with X-ray Excited Luminescence Chemical Imaging Through Tissue
Published on: September 30, 2022
11:26Integrating a Triplet-triplet Annihilation Up-conversion System to Enhance Dye-sensitized Solar Cell Response to Sub-bandgap Light
Published on: September 12, 2014