Related Experiment Video
Updated: Jul 12, 2025

Author Spotlight: 3D Movement Assessment of Maxillary Posterior Teeth in Clear Aligner Treatment
Published on: February 23, 2024
Effectiveness of miniscrew-supported maxillary molar distalization according to temporary anchorage device features
Objectives:
To evaluate the effectiveness of distalizing maxillary first molars (U6) by temporary anchorage devices (TADs) according to their location (palatal, buccal, and zygomatic), their number, and appliance design.
Materials And Methods:
An electronic search of maxillary molar distalization with TADs was done through April 2023. After study selection, data extraction, and risk-of-bias assessment, meta-analyses were performed for the extent of distalization, distal tipping, and vertical movement of U6 using the generic inverse variance and random-effects model. The significance level was set at 0.05.
Results:
Forty studies met the inclusion criteria: 4 randomized controlled trials (RCTs), 13 prospective studies, and 23 retrospective studies (total of 1182 patients). Distalization of the U6 was not significantly greater (P = .64) by palatal (3.74 mm) and zygomatic (3.68 mm) than by buccal (3.23 mm) TADs. Distal tipping was significantly higher (P < .001) in nonrigid (9.84°) than in rigid (1.97°) appliances. Vertical movement was mostly intrusive and higher but not significantly different (P = .28) in zygomatic anchorage (-1.16 mm).
Conclusions:
Distalization of U6 with TADs can be an effective and stable treatment procedure, especially when performed with rigid palatal appliances. However, further RCTs or prospective cohort studies are strongly recommended to provide more clinical evidence.