Related Experiment Video
Updated: Jul 12, 2025

Author Spotlight: Developing a Disposable Dosator for Preclinical Testing of Dry Powder Inhalers in Small Animal Models
Published on: August 18, 2023
Accuracy of liquid drug dose measurements using different tools by caregivers: a prospective observational study
Burcu Bayraktar Balıkçı1, Ülkü Güneş2
1Department of Anesthesiology and Reanimation, Faculty of Medicine Hospital, Ege University, 35040, Izmir, Turkey. burcu.byrktr@hotmail.com.
Insights
Caregivers frequently made medication dosing errors, with dosing cups being the least accurate tools. Oral syringes and spoons proved more reliable for accurate liquid medication measurement in children.
Area of Science:
- Pediatric pharmacology
- Medication safety
- Health sciences research
Background:
- Inaccurate liquid medication dosing by caregivers is a significant concern.
- Dosing cups are commonly provided with liquid medicines but are often inaccurate.
- Recommendations from the American Academy of Pediatrics and U.S. Food and Drug Administration advise using standardized measuring devices.
Purpose of the Study:
- To evaluate the accuracy of liquid medication dose measurements by caregivers.
- To identify factors influencing measurement accuracy.
- To compare the error rates of different dosing instruments.
Main Methods:
- 176 caregivers of children under 8 years old participated.
- Caregivers attempted to measure a 2.5-mL liquid medication dose.
- Accuracy was assessed using dosing cups, droppers, spoons, and oral syringes, compared against a reference weight.
- A margin of error of ±20% was considered clinically significant.
Main Results:
- Caregivers exhibited significant dosing errors, particularly with dosing cups (43% for 15-mL, 37% for 30-mL).
- Oral syringes (4%) and dosing spoons (4.5%) showed the lowest error rates.
- Caregiver role and health literacy did not significantly impact dosing accuracy.
Conclusions:
- Dosing cups are associated with the highest medication dosing errors.
- Oral syringes and dosing spoons are more accurate and recommended for home use.
- Healthcare providers should educate caregivers on using appropriate liquid medication measurement tools, emphasizing oral syringes and dosing spoons.
Abstract:
This study aimed to assess the accuracy of liquid drug dose measurements made by caregivers and explore the factors influencing these measurements. Caregivers (n = 176) of children aged less than 8 years, who were treated at the pediatric clinic of a university hospital in Turkey between July and October 2019, were eligible to participate in this study. The caregivers' ability to accurately measure a 2.5-mL dose of medication was observed using standardized measurement instruments, including 15-mL and 30-mL dosing cups, a 3-mL dropper, a 5-mL dose spoon, and a 5-mL oral syringe. A comparison was made with the reference weight determined for the 2.5-mL dose to calculate the margin of error. A dose of ± 20% of the reference value was considered a clinically significant error. The chi-square test was used to examine differences in dose error rates concerning individual characteristics. Caregivers exhibited a dosing error rate exceeding 20%. Specifically, 43% of the errors occurred when using 15-mL cups, 37% with 30-mL cups, 22% with 3-mL droppers, 4.5% with 5-mL spoons, and 4% with 5-mL syringes. In cases where errors were under 20%, the rates were as follows: 1.1% with 15-mL cups, 2.8% with 30-mL cups, 19% with 3-mL droppers, 3.4% with 5-mL spoons, and 4% with 5-mL syringes. The dosing errors were not affected by the role and health literacy level of caregivers, regardless of the type of dosing tool they used (all p values > 0.05). The study found that oral syringes and dosing spoons had the lowest error rates, whereas dosing cups had the highest error rates. Conclusion: Healthcare providers in family health centers and pediatric clinics should educate caregivers about proper drug administration with oral syringes and dosing spoons, even if dosing cups are included. What is Known: • Dose calculation errors and incorrect measurement tools are the leading factors causing errors. • Liquid medicine bottles are still often accompanied by dosing cups as measuring instruments. • Both the American Academy of Pediatrics (AAP) and the U.S. Food and Drug Administration (FDA) recommend that parents use standard measuring instruments such as oral syringes, droppers, and measuring spoons instead of kitchen spoons for administering the correct dose to children. What is New: • The measuring tool with the maximum errors was the dosing cup, whereas oral syringes and dosing spoons were more accurate. • Individual administering medication at home and the health literacy level had no effect on the accuracy of dose measurement. • Pediatric nurses, in particular, should incorporate safe liquid medication measurement tools into parental education.
Related Concept Videos
Drug Concentrations: Measurements
Plasma...
Uncertainty in Measurement: Accuracy and Precision
Dosage Regimen: Fixed Dose
Fixed-dose regimens can be used for various routes of administration, including intravenous (IV) injections and oral medications. For IV administration, a predetermined amount of the drug is...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Uncertainty in Measurement: Reading Instruments
Drug Dosage Regimen: Overview
Typically, the starting dose and dosing interval are guided by the manufacturer's recommendations based on clinical trials conducted during and after drug...