Related Experiment Video
Updated: May 12, 2025

Digital Planimetry for Assessing Wound Closure Kinetics in a Mouse Model
Published on: January 10, 2025
Comparing Digital, Mobile and Three-Dimensional Methods in Pressure Injury Measurement: Agreement in Surface Area and
1Department of Fundamental of Nursing, Faculty of Health Science, Mehmet Akif Ersoy University, Burdur, Turkey.
Aim:
To examine the consistency among three wound measurement methods in assessing pressure injury surface area and to compare manual depth measurement with three-dimensional wound measurement.
Design:
Methodological and comparative study.
Methods:
This study was conducted between 2022 and 2024 at a university hospital, involving 125 pressure injuries. The wound surface area was measured using three different methods, and depth was measured using a sterile cotton swab and three dimensional wound measurement method. STARD reporting guidelines were followed.
Results:
This study found a statistically significant, strong positive correlation among the three wound measurement methods. However, a significant difference was detected, with digital planimetry yielding higher values than other methods. No significant difference was observed between depth measurement methods.
Conclusion:
Digital wound measurement methods are fast, non-contact, accurate and reliable for assessing pressure injury surface area. Additionally, three dimensional wound measurement serves as a potential aseptic, non-contact alternative to traditional depth measurement, making it a valuable tool in clinical settings.
Implications For The Profession And/Or Patient Care:
Future advancements in wound measurement should focus on artificial intelligence-driven wound boundary detection and improved automation for more consistent and reliable measurements.
Impact:
The study addressed the absence of a universally accepted 'gold standard' for wound measurement. Findings showed that digital planimetry provided the highest measurements, while three-dimensional wound measurement and imitoMeasure demonstrated accuracy, reliability and efficiency. This research will impact wound care specialists and healthcare institutions by improving pressure injury measurement and promoting standardised digital methods in clinical practice.
Patient Or Public Contribution:
No Patient or Public Contribution.
Trial Registration:
NCT06559657.
Related Concept Videos
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Data Collection III
The principles to begin the physical assessment include conducting a comprehensive or problem-related history in a quiet, well-lit room, emphasizing privacy and comfort for the...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:

