Comparison of Motion Grading in 1,000 Patients by First- and Second-Generation HR-pQCT: A Propensity Score Matched
Mikolaj Bartosik1, Alexander Simon2, André Strahl2
1Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
Abstract:
In-vivo bone microstructure measured by high-resolution peripheral quantitative computed tomography (HR-pQCT) is gaining importance in research and clinical practice. Second-generation HR-pQCT (XCT2) shows improved image quality and shorter measurement duration compared to the first generation (XCT1). Predicting and understanding the occurrence of motion artifacts is crucial for clinical practice. We retrospectively analyzed data from HR-pQCT measurements at the distal radius and tibia of 1,000 patients (aged 20 to 89) evenly distributed between both generations of HR-pQCT. Motion artifacts were graded between 1 (no motion) and 5 (severe motion), with grades greater 3 considered unusable. Additionally, baseline characteristics and patients' muscle performance and balance were measured. Various group comparisons between the two generations of HR-pQCT and regression analyses between patient characteristics and motion grading were performed. The study groups of XCT1 and XCT2 did not differ by age (XCT1: 64.9 vs. XCT2: 63.8 years, p = 0.136), sex (both 74.5% females, p > 0.999), or BMI (both 24.2 kg/m2, p = 0.911) after propensity score matching. XCT2 scans exhibited significantly lower motion grading in both extremities compared to XCT1 (Radius: p < 0.001; Tibia: p = 0.002). In XCT2 motion-corrupted scans were more than halved at the radius (XCT1: 35.3% vs. XCT2: 15.5%, p < 0.001), and at the tibia the frequency of best image quality scans was increased (XCT1: 50.2% vs. XCT2: 63.7%, p < 0.001). The strongest independent predictor for motion-corrupted images is the occurrence of high motion grading at the other scanning site during the same consultation. The association between high motion grading in one scan and a corresponding high motion grading in another scan within the same session suggests a non-resting patient. Additionally, aged, female, and patients with smaller stature tend towards higher motion grading, requiring special attention to a correct extremity fixation.
More Related Videos
08:02Author Spotlight: Enhanced Quantification of Cardiovascular Calcification Progression for Longitudinal Micro PET/CT Studies in Small Research Animals
Published on: November 15, 2024
06:31Author Spotlight: Enhancing Rheumatoid Arthritis Research Through HR-pQCT Imaging Analysis
Published on: October 6, 2023
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT