Non-contrast low-dose CT can be used for volumetry of ADPKD
Jaeyeong Yoo1, Jin Up Kim1, Jisu Kim1
1Department of Internal Medicine, Hallym University Medical Center, Chuncheon Sacred Heart Hospital, Chuncheon-si, Gangwon-do, 24253, Republic of Korea.
Background:
Kidney volume provides important information for the diagnosis and prognosis of autosomal dominant polycystic kidney disease (ADPKD), as well as for the evaluation of the effects of drugs such as tolvaptan. Non-contrast computed tomography (CT) is commonly used for volumetry, and this study examined the correspondence and correlation of kidney volume measured by standard-dose or low-dose CT.
Methods:
Axial standard-dose and low-dose CT images with 1-mm slices were obtained from 24 ADPKD patients. The kidney was segmented in the Synapse 3D software and the kidney volume was calculated using stereology. The kidney volume was compared between the two sets of images using R2, Bland-Altman plots, coefficient of variation, and intra-class correlation coefficients (ICCs).
Results:
The mean age of the 24 patients was 48.4 ± 10.9 years, and 45.8% were men (n = 11). The mean total kidney volume on standard-dose CT was 1501 ± 838.2 mL. The R2 of volume between standard-dose and low-dose CT was 0.995. In the Bland-Altman plot, except for one case with a large kidney volume, the two measurements were consistent, and the coefficient of variation and ICC were also good (0.02, 0.998). The CT radiation dose (dose-length product) was 229 ± 68 mGy·cm for standard-dose CT and 50 ± 19 mGy·cm for low-dose CT. A comparable volume was obtained with 20% of the radiation dose of standard-dose CT.
Conclusions:
Standard-dose and low-dose CT showed comparable kidney volume in ADPKD. Therefore, low-dose CT can substitute for ADPKD volumetry while minimizing radiation exposure.
More Related Videos
10:26A Multicenter MRI Protocol for the Evaluation and Quantification of Deep Vein Thrombosis
Published on: June 2, 2015
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies I: Kidney, Ureter, and Bladder Studies
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...