Development of energy efficient design proposals for air conditioned mosques: Temperate humid climate case
1Building Physics Research Group, Department of Architecture, Yildiz Technical University, Istanbul, 34349, Turkey.
Abstract:
Mosques, which are types of religious buildings, are large buildings where many people pray at the same time. The diversity of the user type and density and the variability of the usage schedule make it difficult to establish the homogeneous thermal comfort of these large-volume public buildings. At the same time, the energy consumption in the buildings should be minimal in nowadays when the conventional energy sources decrease. The aim of this study is to evaluate created design strategies for designers and users in order to minimize energy consumption by determining the passive design criteria and choosing the type of air conditioning equipment while providing an acceptable thermal comfort level in mosques. According to the method created for the aim, the scenarios of mosques were compared in terms of thermal comfort and energy consumption in the temperate humid climate conditions. This method includes the analysis of scenarios created from the change of design parameters of mosques (plan, size, roof type of the mosques) with a simulation software which was validated with actual utility data. The suggestions were presented for the selection and design of the mechanical system as a result of the implementation of the created method. When the design scenarios of mosques are compared, the air conditioning of the indoor with radiant method consumed less energy than HVAC equipment with fan system. In accordance with the plan schemes (square, rectangle, circular), the least energy consumption per unit area was in the circular plan scheme and hemispherical design. Compared to the roof types (single dome, multi dome, pyramidal roof, flat roof), the most energy consumption per unit area was generally in the multi dome design. According to the average energy consumption values of the HVAC systems, there was 23 % less energy consumption in the flat plan type (105.06 kWh/m2) compared to the rectangular plan type (129.2 kWh/m2). In the intermittent use schedule of the HVAC system, 8 % more energy was consumed than in the continuous use schedule. According to the air changes per hour in the mosques, there was 5.93 % more energy consumption in 2 ach conditions compared to 0.5 ach conditions.
More Related Videos
07:18Experimental System of Solar Adsorption Refrigeration with Concentrated Collector
Published on: October 18, 2017
10:36Author Spotlight: Optimization of Airflow Velocities in Battery Cooling Systems for Enhanced Thermal Performance and Reduced Energy Consumption
Published on: November 3, 2023
Related Concept Videos
Masonry in Cold and Hot Weather Conditions
Other key practices include keeping masonry units...
Thermal Insulation in Masonry Walls
External insulation can be applied using an Exterior Insulation and Finish System (EIFS), which involves affixing panels of plastic foam to the wall and covering them with a polymeric stucco reinforced with glass fiber mesh....
Design Example: Sustainability in Concrete Building
There are multiple approaches to achieve sustainability in a commercial concrete building. For instance, construct a concrete parking area under the building, utilizing pervious concrete paver blocks in open areas to facilitate rainwater collection through an underground...
Hot Weather Concreting
Mitigating the heat increase in concrete can be economically achieved by shading aggregate stockpiles to prevent heating from solar radiation,...
Design Example: Managing Concrete Workability
Mass Concreting
To reduce the risk of such cracking, the concrete mix may incorporate low-heat cement and pozzolans to reduce the temperature rise. Pre-cooled angular aggregates and water-reducing admixtures...