Related Experiment Video
Updated: Jul 12, 2025

In vitro Assessment of Aortic Regurgitation Using Four-Dimensional Flow Magnetic Resonance Imaging
Published on: February 25, 2022
Echocardiography Versus Magnetic Resonance Imaging Quantification and Novel Algorithm for Isolated Severe Tricuspid
Tom Kai Ming Wang1, Reza Reyaldeen1, Kevser Akyuz1
1Section of Cardiovascular Imaging.
Abstract:
Transthoracic echocardiography (TTE) is the first-line tool to evaluate isolated tricuspid regurgitation (TR) but it has limitations and its TR quantification compared with magnetic resonance imaging (MRI) has been studied infrequently. We compared isolated severe TR quantification by TTE against MRI and developed a novel TTE-based algorithm. Isolated TR patients graded severe by TTE and who underwent MRI January 2007 to June 2019 were studied. The TTE and MRI measurements were analyzed by correlation, area under receiver-operative characteristics curve (AUC), and classification and regression tree algorithm of TTE parameters to best identify MRI-derived severe TR (regurgitant volume ≥45 ml and/or fraction ≥50%). A total of 108 of 262 (41%) that were graded as severe TR by TTE also had severe TR by MRI. There were moderate correlations between TTE and MRI in the quantification of TR severity and right atrial size (Pearson r = 0.428 to 0.645) but none to modest correlations between them in right ventricle quantification. The key TTE parameters to identify MRI-derived severe TR in the decision tree regression algorithm were right atrial volume indexed ≥47 ml/m2 and effective regurgitant orifice area ≥0.45 cm2 and especially if there is right ventricle free wall strain ≥ -9.5%. This novel algorithm has an AUC of 0.76% and 79% agreement to detect severe TR by MRI, which higher than the American Society of Echocardiography criteria with AUC 0.68% and 66% agreement (p = 0.006 and p <0.001, respectively). In conclusion, TTE-derived TR and right atrial quantification had moderate correlation and discrimination of severe TR by MRI, from which a novel TTE algorithm was derived, which had incrementally a higher accuracy than contemporary guidelines' criteria alone.
More Related Videos
11:50High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart
Published on: July 9, 2010
09:29Echocardiographic Assessment of the Right Heart in Mice
Published on: November 27, 2013
Related Concept Videos
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Mitral Stenosis II: Clinical features and Diagnostic Tests
Rheumatic Heart Disease II: Clinical Manifestations and Diagnostic Studies
Mitral Regurgitation II: Clinical Features and Diagnostic Tests