Related Experiment Video
Updated: Jul 12, 2025

Simultaneous Laryngopharyngeal and Conventional Esophageal pH Monitoring
Published on: December 14, 2020
Composite score of physiomechanical esophageal function using functional lumen imaging probe panometry in
Dustin A Carlson1, Ikuo Hirano1, Nirmala Gonsalves1
1Kenneth C. Griffin Esophageal Center of Northwestern Medicine, Department of Medicine, Division of Gastroenterology and Hepatology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA.
Background And Aims:
The evaluation provided by functional lumen imaging probe (FLIP) panometry includes esophageal distensibility/compliance (mechanics) of the esophageal body and esophagogastric junction (EGJ) and esophageal motility (secondary peristalsis). We developed a composite score using these parameters to characterize physiomechanical function in patients with eosinophilic esophagitis (EoE).
Methods:
Two hundred fifteen adult patients with EoE who completed FLIP panometry during sedated endoscopy with esophageal biopsy sampling were included. FLIP metrics of esophageal body Compliance, Contractile response, Distensibility plateau, and maximum EGJ Diameter (C2D2) were scored as 0 for normal versus 1 or 2 for increasing degree of abnormality. Scores were summed to calculate the composite C2D2 score.
Results:
The C2D2 score had a significant positive correlation with mucosal eosinophil count (ρ = .241) and total Endoscopic EoE Reference Score (ρ = .467). Among 46 patients off treatment at the baseline evaluation, future proton pump inhibitor (PPI) responders (ie, achieved mucosal eosinophil count <15 per high-powered field after PPI treatment) had lower C2D2 scores than PPI nonresponders (median, 2 [interquartile range, 1-3] vs 4 [interquartile range, 2-6], respectively; P = .003). A regression model (that controlled for age, sex, and baseline eosinophil count) showed a C2D2 score ≤3 had an odds ratio of 14.5 (95% confidence interval, 2.6-85) to predict future PPI response. However, total Endoscopic EoE Reference Scores (P = .142) and baseline eosinophil count (P = .480) did not differ between PPI responders and PPI nonresponders.
Conclusions:
This composite score of FLIP panometry metrics, the C2D2 score, may facilitate characterizing physiomechanical function in EoE and serve as an objective outcome measure.
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...
Esophagus
The movement of edibles from the pharynx into the esophagus is facilitated by the upper esophageal sphincter, which is formed primarily by the...
Esophageal Strictures-II: Clinical Features and Management
Healthcare providers should gather a comprehensive medical history and conduct a physical examination for diagnosis. If esophageal stricture is...
Barrett Esophagus-II: Clinical Manifestations and Management
To diagnose Barrett's esophagus, healthcare providers often recommend an endoscopy for those showing symptoms of acid reflux. The procedure...