Related Experiment Video
Updated: Jul 12, 2025

Real-Time DC-dynamic Biasing Method for Switching Time Improvement in Severely Underdamped Fringing-field Electrostatic MEMS Actuators
Published on: August 15, 2014
Nonlinear Dynamic Analysis of an Electrostatically Actuated Clamped-Clamped Beam and Excited at the Primary and
1Department of Mechanical Engineering, Jazan University, Jazan 45142, Saudi Arabia.
Abstract:
This work investigates the primary and secondary resonances of an electrostatically excited double-clamped microbeam and its feasibility to be used for sensing applications. The sensor design can be excited directly in the vicinity of the primary and secondary resonances. This excitation mechanism would portray certain nonlinear phenomena and it would certainly lead in increasing the sensitivity of the device. To achieve this, a nonlinear beam model describing transverse deflection based on the Euler-Bernoulli beam theory was utilized. Then, a reduced-order model (ROM) considering all geometric and electrical nonlinearities was derived. Three different techniques involving time domain, fast Fourier transforms (FFTs), and frequency domain (FRCs) were used to examine the appearance of subharmonic resonance of order of one-half under various excitation waveforms. The results show that higher forcing levels and lower damping are required to activate this resonance. We note that as the forcing increases, the size of the instability region grows fast and the size of the unstable region increases rapidly. This, in fact, is an ideal place for designing bifurcation inertia MEMS sensors.
Related Concept Videos
Shearing Stresses in a Beam: Problem Solving
Forced Oscillations
Elastic Curve from the Load Distribution
For all beams, the analysis of the beam's reaction to distributed loads begins by understanding the relationship between a beam's load and the resulting shear forces and bending moments.
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...
Principal Stresses in a Beam
Analyzing principal stresses is crucial, especially in...
Beams with Unsymmetric Loadings
The first moment-area theorem determines the slope at any point on the beam. This theorem indicates that the change in slope between two points on a beam...