Detection and Quantification of Bisphenol A in Surface Water Using Absorbance-Transmittance and Fluorescence
Thomas Ingwani1, Nhamo Chaukura2, Bhekie B Mamba1
1Institute for Nanotechnology and Water Sustainability, College of Engineering, Science and Technology, University of South Africa, Johannesburg 1709, South Africa.
Abstract:
In the present protocol, we determined the presence and concentrations of bisphenol A (BPA) spiked in surface water samples using EEM fluorescence spectroscopy in conjunction with modelling using partial least squares (PLS) and parallel factor (PARAFAC). PARAFAC modelling of the EEM fluorescence data obtained from surface water samples contaminated with BPA unraveled four fluorophores including BPA. The best outcomes were obtained for BPA concentration (R2 = 0.996; standard deviation to prediction error's root mean square ratio (RPD) = 3.41; and a Pearson's r value of 0.998). With these values of R2 and Pearson's r, the PLS model showed a strong correlation between the predicted and measured BPA concentrations. The detection and quantification limits of the method were 3.512 and 11.708 micro molar (µM), respectively. In conclusion, BPA can be precisely detected and its concentration in surface water predicted using the PARAFAC and PLS models developed in this study and fluorescence EEM data collected from BPA-contaminated water. It is necessary to spatially relate surface water contamination data with other datasets in order to connect drinking water quality issues with health, environmental restoration, and environmental justice concerns.
More Related Videos
08:13A Filter-based Surface Enhanced Raman Spectroscopic Assay for Rapid Detection of Chemical Contaminants
Published on: February 19, 2016
11:59Extraction and Detection of Geosmin and 2-Methylisoborneol in Water and Fish using High-Capacity Sorptive Extraction Probes and GC-MS
Published on: July 3, 2025
Related Concept Videos
Transmission Electron Microscopy
High-Performance Liquid Chromatography: Types of Detectors
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
Atomic Absorption Spectroscopy: Overview
When irradiated by EMR of a particular wavelength, these...
Atomic Emission Spectroscopy: Overview
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.