Related Experiment Video
Updated: Jul 12, 2025

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Assessment of extremity dose for medical staff involved in positron emission tomography/computed tomography imaging:
Rabiye Uslu Erdemir1, Mohamed Mahmoud Abuzaid2,3, Baris Cavli4
1Zonguldak Bülent Ecevit University of Medicine, Department of Nuclear Medicine, Zonguldak, Turkey.
Abstract:
There has been an increase in positron emission tomography (PET)/computed tomography (CT) imaging procedures, and medical workers involved in PET/CT are at increased risk of occupational exposure. Data on extremity dose exposure are limited globally. The current study aimed to evaluate the occupational radiation dose for extremities for medical workers (nurses, radiographers/radiologic technologists, and nuclear medicine physicians) working in PET/CT scanners at 5 large hospitals in Turkey. Optically stimulated luminescence (OSL) and Thermoluminescent dosimeter (TLD) ring dosimeters were used to measure equivalent dose values. Hospitals 1, 2, and 5 used OSL, and 3 and 4 used TLD. A total of 502 readings were obtained from 55 workers. In millisievert (mSv), the average annual effective dose for all workers was 14.5 ± 17.7 (0.2-157.2). A radiography technologist received a maximum dose of 157.21. Nurses received the highest average annual effective dose (15.2 ± 19.46) (0.32-65.58), followed by radiography technologists (14.7 ± 18.03) (0.4-157.2), and nuclear medicine physicians demonstrated the least dose (8.6 ± 10.5) (1.2-24.4). The results show that the extremity dose is well below the annual dose limit of 500 mSv. However, there is a wide variation in dose among the workers, underlining a need for careful assessment of working conditions to ensure safe practices for all workers.
More Related Videos
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation I: X-ray and CT
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...

