Radiofrequency and pulsed electromagnetic field application following liposuction-Clinical evaluation of performance
Kai O Kaye1, Felix Paprottka1, Nicholas Moellhoff2
1Ocean Clinic, Marbella, Spain.
Objective:
With more than 1.5 million performed procedures, liposuction was the second most performed esthetic surgical procedure all over the world in males and in females in the year 2020. The objective of this open-label, evaluator-blinded study was to assess the efficacy and safety of an energy-based device that combines multipolar radiofrequency with pulsed electromagnetic field (PEMF) in patients that underwent liposuction.
Materials And Methods:
A total of 30 subjects, of whom 24 were females (80%), with a mean age of 48.4 ± 11.0 years (range: 27-69 years) and a mean weight of 69.5 ± 11.7 kg underwent unilateral treatment with radiofrequency and application of PEMF after bilateral liposuction. One month after the last of a total of six weekly treatments, skin elasticity, visco-elasticity and net elasticity, as well as subject reported satisfaction on a 5-point scale ranging from -1 (worse) to 3 (very much improved) and esthetic improvement ranging from 0 (very unsatisfied) to 4 (very satisfied) rated by three independent reviewers were assessed.
Results:
Three independent and blinded reviewers rated the improvement of the treated side on average as 1.17 + 0.07 compared with baseline. Subjects were very satisfied with their treatment, with a mean score of 3.24 (0.03) out of 4 at the 1-month follow-up visit. Cutometer measurements showed no significant changes.
Conclusion:
This study revealed that the subjective satisfaction with the results of the application of RF and PEMF after liposuction is high, while at the same time the esthetic appearance as rated by independent raters improved on the treated side.
More Related Videos
07:58Stromal Vascular Fraction-enriched Fat Grafting for the Treatment of Symptomatic End-neuromata
Published on: November 23, 2017
05:56Evaluation of the Feasibility, Safety, and Accuracy of an Intraoperative High-intensity Focused Ultrasound Device for Treating Liver Metastases
Published on: January 9, 2019
Related Concept Videos
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...