Active Breathing Coordinator reduces radiation dose to the stomach in patients with left breast cancer
Ying Piao1, Hongtao Chen1, Fengshun Yuan2
1Department of Radiation Oncology, Shenzhen People's Hospital (The Second Clinical Medical College, Jinan University; The First Affiliated Hospital, Southern University of Science and Technology), Shenzhen, Guangdong, People's Republic of China.
Background/Purpose:
Gastric dose parameters comparison for deep inspiration breath-hold (DIBH) or free breathing (FB) mode during radiotherapy (RT) for left-sided breast cancer patients (LSBCPs) has not been investigated before. This study aimed to analyze the impact of Active Breath Coordinator (ABC)-DIBH technique on the dose received by the stomach during RT for LSBCPs and to provide organ-specific dosimetric parameters.
Materials And Methods:
The study included 73 LSBCPs. The dosimetric parameters of the stomach were compared between FB and DIBH mode. The correlation between the stomach volume and dosimetric parameters was analyzed.
Results:
Compared to FB mode, statistically significant reductions were observed in gastric dose parameters in ABC-DIBH mode, including Dmax (46.60 vs 17.25, p < 0.001), D1cc (38.42 vs 9.60, p < 0.001), Dmean (4.10 vs 0.80, p < 0.001), V40Gy (0.50 vs 0.00, p < 0.001), V30Gy (6.30 vs 0.00, p < 0.001), V20Gy (20.80 vs 0.00, p < 0.001), V10Gy (51.10 vs 0.77, p < 0.001), and V5Gy (93.20 vs 9.60, p < 0.001). ABC-DIBH increased the distance between the stomach and the breast PTV when compared to FB, from 1.3 cm to 2.8 cm (p < 0.001). Physiologic decrease in stomach volume was not found from FB to ABC-DIBH (415.54 cm3 vs 411.61 cm3, p = 0.260). The stomach volume showed a positive correlation with V40Gy (r2 = 0.289; p < 0.05), V30Gy (r2 = 0.287; p < 0.05), V20Gy (r2 = 0.343; p < 0.05), V10Gy (r2 = 0.039; p < 0.001), V5Gy (r2 = 0.439; p < 0.001), Dmax (r2 = 0.269; p < 0.05) and D1cc (r2 = 0.278; p < 0.05) in FB mode. While in ABC-DIBH mode, most stomach dosimetric parameters were not correlated with gastric volume.
Conclusions:
The implementation of ABC-DIBH in LSBCPs radiotherapy resulted in lower irradiation of the stomach. Larger stomach volume was associated with statistically significantly higher dose irradiation in FB mode. To reduce radiotherapy related side effects in FB mode, patients should be fast for at least 2 hours before the CT simulation and treatment.
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation I: X-ray and CT
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...