Assessing dead time effects when attempting isotope ratio quantification by time-of-flight secondary ion mass
Laura C Baqué1, Federico M Cabello2, Federico A Viva2
1Nanoscience and Nanotechnology Institute (CNEA-CONICET), Department of Materials Characterization, Bariloche Atomic Center, Av. Bustillo 9500, S. C. de Bariloche, Río Negro R8402AGP, Argentina.
Abstract:
Time-of-flight secondary ion mass spectrometry (TOF-SIMS) is a quasi-non-destructive technique capable of analyzing the outer monolayers of a solid sample and detecting all elements of the periodic table and their isotopes. Its ability to analyze the outer monolayers resides in sputtering the sample surface with a low-dose primary ion gun, which, in turn, imposes the use of a detector capable of counting a single ion at a time. Consequently, the detector saturates when more than one ion arrives at the same time hindering the use of TOF-SIMS for quantification purposes such as isotope ratio estimation. Even though a simple Poisson-based correction is usually implemented in TOF-SIMS acquisition software to compensate the detector saturation effects, this correction is only valid up to a certain extent and can be unnoticed by the inexperienced user. This tutorial describes a methodology based on different practices reported in the literature for dealing with the detector saturation effects and assessing the validity limits of Poisson-based correction when attempting to use TOF-SIMS data for quantification purposes. As a practical example, a dried lithium hydroxide solution was analyzed by TOF-SIMS with the aim of estimating the 6Li/7Li isotope ratio. The approach presented here can be used by new TOF-SIMS users on their own data for understanding the effects of detector saturation, determine the validity limits of Poisson-based correction, and take into account important considerations when treating the data for quantification purposes.
Related Concept Videos
Mass Spectrometry: Isotope Effect
Tandem Mass Spectrometry
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
Mass Analyzers: Common Types
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Radioactive Decay and Radiometric Dating