Commercially-available AI algorithm improves radiologists' sensitivity for wrist and hand fracture detection on X-ray, compared to a CT-based ground truth
Related Experiment Video
Updated: Jul 11, 2025

Assessment of Bone Fracture Healing Using Micro-Computed Tomography
Published on: December 9, 2022
Thibaut Jacques1,2, Nicolas Cardot3, Jeanne Ventre4
1Department of Musculoskeletal Radiology, Lille University Hospital, Rue du Professeur Emile Laine, 59000, Lille, France. thib.jacques@gmail.com.
Objectives:
Algorithms for fracture detection are spreading in clinical practice, but the use of X-ray-only ground truth can induce bias in their evaluation. This study assessed radiologists' performances to detect wrist and hand fractures on radiographs, using a commercially-available algorithm, compared to a computerized tomography (CT) ground truth.
Methods:
Post-traumatic hand and wrist CT and concomitant X-ray examinations were retrospectively gathered. Radiographs were labeled based on CT findings. The dataset was composed of 296 consecutive cases: 118 normal (39.9%), 178 pathological (60.1%) with a total of 267 fractures visible in CT. Twenty-three radiologists with various levels of experience reviewed all radiographs without AI, then using it, blinded towards CT results.
Results:
Using AI improved radiologists' sensitivity (Se, 0.658 to 0.703, p < 0.0001) and negative predictive value (NPV, 0.585 to 0.618, p < 0.0001), without affecting their specificity (Sp, 0.885 vs 0.891, p = 0.91) or positive predictive value (PPV, 0.887 vs 0.899, p = 0.08). On the radiographic dataset, based on the CT ground truth, stand-alone AI performances were 0.771 (Se), 0.898 (Sp), 0.684 (NPV), 0.915 (PPV), and 0.764 (AUROC) which were lower than previously reported, suggesting a potential underestimation of the number of missed fractures in the AI literature.
Conclusions:
AI enabled radiologists to improve their sensitivity and negative predictive value for wrist and hand fracture detection on radiographs, without affecting their specificity or positive predictive value, compared to a CT-based ground truth. Using CT as gold standard for X-ray labels is innovative, leading to algorithm performance poorer than reported elsewhere, but probably closer to clinical reality.
Clinical Relevance Statement:
Using an AI algorithm significantly improved radiologists' sensitivity and negative predictive value in detecting wrist and hand fractures on radiographs, with ground truth labels based on CT findings.
Key Points:
• Using CT as a ground truth for labeling X-rays is new in AI literature, and led to algorithm performance significantly poorer than reported elsewhere (AUROC: 0.764), but probably closer to clinical reality. • AI enabled radiologists to significantly improve their sensitivity (+ 4.5%) and negative predictive value (+ 3.3%) for the detection of wrist and hand fractures on X-rays. • There was no significant change in terms of specificity or positive predictive value.
Related Concept Videos
X-ray Imaging
Radiological Investigation I: X-ray and CT
Ultrasonography
During an ultrasonography procedure, a handheld device called...

