An improved method for rapid and safe preparation and measurement of dimethylmercury using gas chromatography-atomic
Yingying Chen1, Qingzhe Zhang1, Lian Zhang1
1Shandong Key Laboratory of Environmental Processes and Health, Qingdao Key Laboratory of Marine Pollutant Prevention, School of Environmental Science and Engineering, Shandong University, Qingdao 266237, China.
Abstract:
Transformations between dimethylmercury (DMHg) and other mercury (Hg) species have been one of the critical knowledge gaps in the Hg global biogeochemical cycle due to the lack of detailed studies. The preparation and measurement of DMHg are challenging due to the high toxicity and volatility of DMHg. In this work, we invented a new DMHg generator for successfully preparing high-purity DMHg in a highly controllable and safe way. The DMHg could be spontaneously volatilized and diffused from the original preparation solution to the solution to be studied. The parameters for generating DMHg were optimized to be the pH value of 4.0 with a MeCo/Hg2+ molar ratio of 10 at 20 °C. The following measurement method of DMHg in the presence of various species of Hg was also investigated and optimized. Hg0 and DMHg could be separated effectively with the carrier gas flow rate of 15 mL min-1 and the gas chromatography column temperature of 30 °C. The interferences of Hg0, monomethylmercury and other species were excluded by systematic control experiments. A sensitive and reliable approach for quantifying trace DMHg in water was developed. Under the optimal conditions, the limits of detection for Hg0, MMHg and DMHg were 0.03, 0.002 and 0.024 ng L-1, respectively, with the relative standard deviation below 8.2%. The developed method was validated by the determination Hg species of different natural water samples. This work is expected to provide a new and safe strategy for DMHg preparation and a verified method for DMHg measurement.
More Related Videos
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Atomic Absorption Spectroscopy: Atomization Methods
Precipitation Gravimetry
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...