Flowchart for predicting achieving the target area under the concentration-time curve of vancomycin in critically ill
Tomoyuki Ishigo1, Satoshi Fujii1, Yuta Ibe1
1Department of Pharmacy, Sapporo Medical University Hospital, Sapporo, Japan.
Introduction:
In therapeutic drug monitoring (TDM) of vancomycin (VCM), the area under the concentration-time curve (AUC) is related to the clinical efficacy and toxicity. Therefore, herein, we examined the factors associated with achieving the target AUC at follow-up and developed a decision flowchart for achieving the target AUC in critically ill patients.
Methods:
This multicenter retrospective observational study was conducted at eight hospitals. We retrospectively analyzed data from patients who had received VCM in the intensive care unit from January 2020 to December 2022. Decision-tree (DT) analysis was performed using factors with p < 0.1 in univariate analysis as the independent variables. Case data were split up to two times, and four subgroups were included. The primary endpoint was achieving the target AUC at the follow-up TDM (AUCfollow-up) and target AUCfollow-up achievement was defined as an AUC of 400-600 μg‧h/mL. The initial AUC values were calculated with the 2-point concentrations (peak and trough) using the Bayesian estimation software Practical AUC-guided TDM (PAT).
Results:
Among 70 patients (median age [interquartile range], 66 [56, 79] years; 50 % women), the AUCfollow-up was achieved in 70 % (49/70). Three factors were selected for the decision flow chart: predicted AUCfollow-up of 400-600 μg‧h/mL, dosing at 12-h intervals, and CCr of 130 mL/min/1.73 m2 or higher; the accuracy was adequate (92 %, R2 0.52).
Conclusion:
We successfully identified the factors associated with achieving the target AUC of VCM at follow-up TDM and developed a simple-to-use DT model. However, the validity of the findings needs to be evaluated.
Related Concept Videos
Drug Concentration Versus Time Correlation
Two pivotal parameters are the minimum effective concentration (MEC) and the minimum toxic concentration (MTC). The MEC is the...
Rational Dosage Regimen: Maintenance Dose and Loading Dose
In most cases, drugs are administered repetitively or infused continuously to maintain a steady-state concentration in the body. At a steady...
One-Compartment Open Model for IV Bolus Administration: Estimation of Elimination Rate Constant, Half-Life and Volume of Distribution
One-Compartment Model: IV Infusion
The one-compartment model for IV infusion uses mathematical equations to describe the rate of change in drug quantity in the body. At steady-state or infusion equilibrium, the drug input...
Time Course of Drug Effect
Two-Compartment Open Model: IV Infusion
The model illustrates the decrease in plasma drug concentration from the central compartment with a specific equation. It shows that under steady-state conditions, the drug's input rate...